background image

Congratulations on your new VENDLET.

The VENDLET is used for handling bedridden clients, 

 

for example:

• 

turning the client to lateral, prone or supine positions

• 

moving the client from one side of the bed to the other

• 

repositioning the client up in the bed

• 

mobilizing the client in and out of bed

This manual covers VENDLET Standard.

 

 

Max. user weight is 250 kg

The instructions in this manual must be followed. Vendlet 

ApS shall not be liable should VENDLET Standard be used, 

modified, or assembled in a way that is not described in this 

manual.

This manual is divided into three parts: 

Part 1 contains general information that is useful to everyone 

responsible for the purchasing, examination, use, assembly, 

and maintenance of VENDLET Standard.

Part 2 is a user manual containing information about the oper-

ation and daily maintenance of VENDLET Standard. 

Part 3 is a technical manual containing information about the 

assembly, maintenance, and service of VENDLET Standard.

Summary of Contents for STANDARD

Page 1: ...VALUE IN CARING MANUAL STANDARD...

Page 2: ...ients in bed Classification rule Class I acc to rule 1 and 13 of annex VIII in EU 2017 745 The product complies with the following standards EN 60601 2 52 2010 Medical electrical equipment Part 2 52 P...

Page 3: ...manual must be followed Vendlet ApS shall not be liable should VENDLET Standard be used modified or assembled in a way that is not described in this manual This manual is divided into three parts Par...

Page 4: ...EVENT OF AN INCIDENT 10 SYMBOLS 11 PART 1 General information PART 2 User manual OPERATION 12 How to use VENDLET Standard 12 Turning 12 Moving from one side of the bed to the other 13 Repositioning t...

Page 5: ...l hand control 32 Battery backup 32 Side rail bumper 32 PART 3 Technical manual Attaching the turning sheet before use 19 What should I do if the turning sheet is rolled askew on the bars 19 Changing...

Page 6: ...ng 34 MAINTENANCE CHECK 35 Annual check 35 Electrical parts 35 Mechanical parts 35 Sheets 35 Functional tests 35 Replacements of parts 35 TROUBLESHOOTING TECHNICIANS 36 TECHNICAL DATA 37 Battery backu...

Page 7: ...lient is very restless in bed or has an untypical anatomy Independent living VENDLET Standard is not designed to be operated by the cli ents themselves However if a risk assessment made by the respons...

Page 8: ...clicking the The emergency release nut must only be used in case of emer gency see page 21 or malfunction of the actuators VENDLET Standard hand control Power with light stop button Tighten the sheet...

Page 9: ...Therefore long loose hair should be collect ed before moving and handling the client Be aware that the client does not get too close to the edge of the bed as there is a risk of falling out of the bed...

Page 10: ...ra compression at the edge of the mattress When alternating air mattresses are used it should be possible to inflate the mattress to a firm state before VENDLET Standard is operated Soft mattresses wi...

Page 11: ...After 2 min of continuous use it requires 18 min rest Max 350W 80 sec 175W 40sec 25 C In continuous use at 25 C 350 W can be supplied for 80 sec then the power consumption will be reduced to 175 W for...

Page 12: ...with VENDLET Standard enables caregivers to work on a one to one basis one hand is used to operate the hand control and the other hand is free to guide the arms and legs of the client In order to impr...

Page 13: ...he button to reduce speed 4 Press the or button on the hand control to move the client to the side towards you 8 The client now lies on his her right side 9 Press the and button to slacken the sheet b...

Page 14: ...r end of the bar 4 1 Turn VENDLET Standard on by double clicking the button 2 Press the and button to to lower the bars if they have been raised 3 If necessary press once or twice on the button to red...

Page 15: ...his her side 4 Place the sling along the back of the client and make sure that the sling is centred and correctly placed in accordance with the instructions of the sling manufacturer 4 5 Use the VENDL...

Page 16: ...is room for breathing 7 To return to a supine position press the button to raise the red bar and press the button to wind the tur ning sheet onto the red bar VENDLET Standard now turns the client to s...

Page 17: ...sure relieving properties of the mattresses To prevent interference with the function of alternating air mattresses the turning sheet must be sufficiently slackened before a client is left unattended...

Page 18: ...side is facing upwards 1 2 2 Fasten the velcro straps around the edge of the mattress support platform It is important that the straps are fas tened around the edge of the platform under the mattress...

Page 19: ...e strip at the opposite edge of the turning sheet into the groove on the other bar 6 Use this bar to pull in the turning sheet by pressing the or button until the sheet covers the mattress evenly with...

Page 20: ...g sheet onto the bar 2 4 5 5 Use the opposite bar to move the client to a supine posi tion on top of the new and the old turning sheets 6 3 4 Allow approx half of the new turning sheet to roll onto th...

Page 21: ...you do not have power 1 Manually lift the bar and directly afterwards activate the emergency release by pushing the emergency release nut upwards 2 Once the bar has been released continue pressing th...

Page 22: ...uld Yes No 3 Are the nylon straps attached to the bed frame and all the support bars Yes No 4 Is the turning sheet in good condition and does the sheet run over the bars Yes No 5 Is the slide sheet fa...

Page 23: ...re During washing all electrical sockets outlets in the control unit and the control unit extension must be fitted with either a cable or a socket cover plug to eliminate ingress of water Equally all...

Page 24: ...en the client is lying in bed Is the turning sheet running under the bars The sheet must be over the bars Are all plugs properly connected on the control unit The hand control buttons are not working...

Page 25: ...and contact the distributor in case of obvious damage Parts list 1 unit Blue side complete 1 unit Red side complete 1 unit Suspension bracket for control unit 1 unit Control unit 1 unit Control unit...

Page 26: ...ttress and the side rail on both sides of the mattress If the distance is above 6 cm the risk of entrapment must be evalu ated for the specific combination of bed mattress patient and VENDLET system L...

Page 27: ...the bed must be at least 317 kg to be able to handle a user weight of 250 kg Max user weight VENDLET Standard Other equipment Required Bed SWL 250 kg 42 kg 25 kg 317 kg In intensive care situations th...

Page 28: ...in the bottom of the bracket Tighten the button head bolt evenly Tighten the bracket at the foot end 3 Place the corner post as close to the headboard as possi ble Fit the button head bolt at the bot...

Page 29: ...at and horizon tal 2 If the mattress is an alternating air mattress make sure it s fully inflated 3 Place the bar in the highest position 4 Press the small button on the corner post 5 Simultaneously l...

Page 30: ...The suspension bracket is now placed correctly Electrical parts Mounting the control unit 4 3 Attach the power cord to the control unit 4 Slide the control unit onto the suspension bracket till it cli...

Page 31: ...s have plugs with yellow O rings these are connected to the yellow control unit colour codes Connecting the control unit The hand control should be connected before the power cable is connected to a m...

Page 32: ...s be placed where it will be visi ble from the bed and in close proximity to the bed ADDITIONAL ACCESSORIES Additional hand control An additional hand control can be connected if a hand control os req...

Page 33: ...c parts intact and without signs of wear Are all wires intact Do both bars slacken and tighten the sheet Does the timer activate when the button is pushed twice within 2 seconds Does the timer turn of...

Page 34: ...the bolts in the mounting plates and turn them aside to lift VENDLET Standard off the bed frame Optionally use the mounting trolley to transport VENDLET Standard to a new destination Storage Store VE...

Page 35: ...end Check all cables plugs and relief cables for damage Check whether the cables are properly secured Check whether the cables are prop erly secured and not hanging loose Check if the actuators run u...

Page 36: ...ature Switch the plugs of the two bars If the same bar still does not work then the motor of that bar is defective If the other bar is not working then the hand control or the control unit is defectiv...

Page 37: ...EU 2017 745 VENDLET Standard is a class I product VENDLET Standard Product no 6300000 Max user weight 250 kg Control unit Power supply SMPS 350W Mains supply 100 220 Volt AC 60 Hz or 100 230 Volt AC...

Page 38: ...This equipment is compliant with IEC 60601 1 2 meaning that no loss of essential performance is found due to electromag netic disturbances The essential performance of VENDLET Standard refers to cont...

Page 39: ......

Page 40: ...All rights reserved Copyright Vendlet ApS Vers 3 0 2021 11 Vendlet ApS Egelund 33 6200 Aabenraa Tel 96 31 00 50 vendlet vendlet dk www vendlet com Manufacturer MD...