background image

Fume Exhaust Fans

17

Parts List

CAUTION

A fan manufactured with an explosion resistant motor 
does not certify the entire unit to be explosion proof. 
Refer to UL Listing Mark for the fans approved usage.

Each fan bears a manufacturer’s nameplate with model number and serial number embossed. This information will 
assist the local Venco representative and the factory in providing service and replacement parts. Before taking any 
corrective action, make certain unit is not capable of operation during repairs.

CAUTION

La présence d’un moteur antidéflagrant sur un 
ventilateur ne garantit pas que tout l’appareil est 
antidéflagrant. Pour connaître les emplois autorisés 
de l’appareil, voir son marquage de conformité UL.

VJC-315 Belt Drive

Shown with optional accessories, 
spring isolators and equipment 
supports.

Stack

Weatherhood
Components

Motor Pulley 
(driver)

Shaft Pulley 
(driven)

Drive Side 
Bearing

Opposite 
Drive Side 
Bearing

Fan Shaft

Heat Slinger

Rub Ring

Shaft Seal

Motor

Restrained Spring Isolators

Equipment Supports

Scroll Housing

Inlet Cone

Inlet Flange

Inlet 
Companion 
Flange

Wheel

Belt(s)

Summary of Contents for VJC-200

Page 1: ...ny stationary objects 3 Motor must be securely and adequately grounded 4 Do not spin fan wheel faster than max cataloged fan RPM Adjustments to fan speed signi cantly effects motor load If the fan RPM...

Page 2: ...e which is sealed to prevent the entry of blowing dust rain or snow Temperatures should be evenly maintained between 30 to 110 F 1 to 43 C wide temperature swings may cause condensation and sweating o...

Page 3: ...age 2 3 Removing from Storage 3 General Information Unit and System Identification Tags 4 Pre Installation Information 4 Electrical Disconnects 4 Moving Parts 4 Guards Motor Cover Weatherhood 4 Access...

Page 4: ...the fan cabinet Pre Installation Information Before installation it is important to be certain the mounting surface will bear the operating weight of the unit For proper unit operation it is also impo...

Page 5: ...stallations Inlet Duct Turns Installation of a duct turn or elbow too close to the fan inlet reduces fan performance because air is loaded unevenly into the fan wheel To achieve full fan performance t...

Page 6: ...epair section of this manual for details involving touch up of damaged surfaces Lift unit before mounting the stack to the fan body Use standard lifting and rigging practices ALL lifting brackets on e...

Page 7: ...rate three common methods used to install roof curbs for fume exhaust systems Methods used to attach a unit are dependent on local codes roof construction design and roof construction materials Consul...

Page 8: ...S equipment supports are designed for use on at roof decks to be mounted directly to the roof deck structure then roofed and ashed for weather tightness The orientation of the equipment support should...

Page 9: ...osed Any increase in fan speed represents a substantial increase in load on the motor To avoid motor overheating and possible burnout motor load amperes should always be checked and compared to namepl...

Page 10: ...ts and centering the cone ring on the wheel If additional adjustment is required to maintain a constant radial gap loosening the bearing bolts and centering the wheel is acceptable as a secondary opti...

Page 11: ...al number for colors other than our standard TOUCH UP PAINT REPAIR KIT CONTENTS One pint of Kem Kromik primer including a technical data sheet One pint of industrial enamel including a technical data...

Page 12: ...ck all guarding to ensure that it is securely attached and not interfering with rotating parts 9 Check all electrical connections for proper attachment 10 Check housing and ductwork if accessible for...

Page 13: ...e entire fan should be checked for tightness 3 Any dirt accumulation on the wheel or in the housing should be removed to prevent unbalance and possible damage 4 Inspect fan impeller and housing lookin...

Page 14: ...cy Do not exceed maximum class fan rpm of the wheel Belt Span De ection Belt Span 64 Recommended Bearing Lubrication Schedule Relubrication Schedule in Months Standard Grease Fan RPM Bearing Bore inch...

Page 15: ...e nozzle preset at the factory based on the order Depending on installed air performance this nozzle can be adjusted in the eld to accommodate the building situation To increase the exhaust velocity a...

Page 16: ...ers procedures for removal and installation 3 Before removing the bearing bolts make sure the shaft is supported slightly Remember to consider the wheel weight on the shaft 4 Remove both bearings from...

Page 17: ...ake certain unit is not capable of operation during repairs CAUTION La pr sence d un moteur antid flagrant sur un ventilateur ne garantit pas que tout l appareil est antid flagrant Pour conna tre les...

Page 18: ...optional curb cap inlet box and inlet flanges Stack Motor Cover Disconnect Switch Motor Plate Motor Integrated Mounting Rails Access Door Curb Cap Isolation Damper Roof Curb Scroll Housing Inlet Cone...

Page 19: ...system Use correction factor to adjust for temperature altitude Resize ductwork Clean lters coils Change fan speed High Motor Amp Draw Fan Check rotation of wheel Reduce fan speed Duct System Resize...

Page 20: ...______ AM PM Notes __________________________________________ ________________________________________________ ________________________________________________ ________________________________________...

Reviews: