- 40 -
Mithos Wi-fi Chronothermostat User Manual
Half the desired regulation band is set in the device.
The range for this parameter is 0.5 ÷ 5.0°C with 0.1°C resolution
The regulation period represents the duration of the regulation cycle (activation period
+ deactivation period)
The value of this parameter is selectable between 10', 20' and 30'
Choose the regulation period value as follows:
• 10' for low thermal inertia systems
• 20' for medium thermal inertia systems
• 30' for high thermal inertia systems
Choose the regulation band value as follows:
• broad band (5°C) for systems with high thermal gradient
• narrow band (0.5°C) for systems with low thermal gradient
Compliance with Community Directives
2014/35/EU (LVD)
2014/30/EU (EMCD)
2014/53/EU (RED)
is declared with reference to the following harmonized standards:
EN 60730-2-7 (LVD)
EN 60730-2-9 (LVD)
ETSI EN 300 328 (R&TTE)
ETSI EN 301 489-1 (EMC-R&TTE)
ETSI EN 301 489-17 (EMC-R&TTE)
REFERENCE STANDARDS