background image

 

Welding control modes

 

The following four welding modes with respect to the digital input are available, 

depending on the value of 

S

 parameter:

b

 

The  option  for 

multi-spark  welding

  is  available  for  all  modes  except  for

 

continuous welding

It can be used by setting parameter 

N

 to a value, greater than 

i

1, for the number of sparks(impulses) when welding non-flat items. In this case, the 
user can set different values for the power of the second (

SP

) and third

 (SP

) sparks. 

2

3

            

- (

Trigger on initial pressing

It is necessary to keep digital input ON for the 

whole phase of pressing (

T

), after that the welding process will continue straight to 

off

the final cooling phase regardless of the input state. A new welding will be triggered 
only from 

ready state

 of the controller, i.e. previous welding finished and digital input 

OFF:

 

        

 

-  (

Repetitive welding

It is necessary to keep digital input ON for the whole 

process  of  welding.  Releasing  the  input  will  stop  the  repetitions  and  bring  the 
controller to 

ready state

. After one weld is completed, there will be a delay of 

T

 

d

seconds before the next one starts:

Fig

.1 

Timing diagram for welding trigger on initial pressing, N =4 and

 

S =0

i

b

        *  The second input triggering does not start real welding

SP

T

off

T

off

T

p

T

p

T

p

T

p

T

p

T

p

T

e

T

e

T

on

T

on

T

on

T

on

T

on

T

on

T

on

T

on

input 

In

T

off

output

4

 * 

 * 

 * 

Fig

.2 

Timing diagram for repetitive welding mode,

 

N

=4 and S =1

i

b

     

     

the digital input is released at the end of third spark of the second weld

delay

input 

In

output

SP

3

SP

2

T

off

T

off

T

p

T

p

T

p

T

p

T

p

T

e

T

on

T

on

T

on

T

on

T

on

T

on

T

on

SP

SP

3

SP

2

T

d

Reviews: