   7

• The control keypad has been tested and found to comply with the 

limits for a Class B digital device, pursuant to part 15 of the FCC Rules. 

These limits are designed to provide reasonable protection against 

harmful interference in a residential installation. The control keypad 

generates, uses and can radiate radio frequency energy and, if not 

installed and used in accordance with the instructions, may cause 

harmful interference to radio communications. However, there is no 

guarantee that interference will not occur in a particular installation. If 

the control keypad does cause harmful interference to radio or televi-

sion reception, which can be determined by turning the control keypad 

off and on, the user is encouraged to try to correct the interference by 

one or more of the following measures: 

- Reorient or relocate the receiving antenna. 

- Increase the separation between the control keypad and receiver. 

 - Connect the control keypad into an outlet on a circuit different from 

  that to which the receiver is connected. 

- Consult the dealer or an experienced radio/TV technician for help.

 Changes or modifications not expressly approved by the party respon-

sible for compliance could void the user's authority to operate the 

control keypad.

• FCC Radiation Exposure Statement: The control keypad complies with 

FCC RF radiation exposure limits set forth for an uncontrolled environ-

ment.

• The term "IC:" before the control keypad certification number only 

signifies that the Industry Canada technical specifications were met.

Installation

• The control keypad is for indoor use only.
• Installation in rooms with a high level of humidity and with hidden 

wiring must comply with relevant regulations (contact a qualified 

electrician if necessary).

• Before fixing the control keypad to the wall, verify that it can operate 

the product in question from the proposed position.  

Product

• The control keypad has a built-in RF (radio frequency) unit and will not 

be operative if placed in a metal cabinet.

• Electrical products must be disposed of in conformity with all local 

codes, ordinances, rules and regulations for electronic waste and not 

with household waste.

• Used batteries must not be disposed of together with household waste 

but have to be disposed of in conformity with the relevant national 

environmental regulations. Batteries contain substances that can be 

harmful if not handled and recycled correctly.

• 

 

Use local authority battery disposal point where available.

• The packaging can be disposed of with usual household waste.
• Radio frequency band: 2.4 GHz.
• Radio frequency range: 110 yards (100 m) free field. Depending on 

building construction, the indoor range is approx 30 ft (10 m). How-

ever, constructions with reinforced concrete, metal ceilings and plaster 

walls with steel members may reduce the range.

Maintenance and service

• The control keypad  requires a minimal amount of maintenance. The 

surface may be cleaned with a soft, damp cloth using a small amount 

of household cleaner diluted in water.

• If you have any technical questions, please contact your VELUX sales 

company, see telephone list or www.velux.com.

io-homecontrol

®

 provides advanced and secure radio technology that is easy to install. 

io-homecontrol

®

  labelled  products  communicate  with  each  other,  improving  comfort, 

security and energy savings.

www.io-homecontrol.com

 

Summary of Contents for INTEGRA KLI 310

Page 1: ...VAS 454332 2018 XX VELUX INTEGRA KLI 310 311 312 ENGLISH Instructions for wall switch ESPA OL Instrucciones para el teclado de control FRAN AIS Instructions pour le bloc num rique KLI 110...

Page 2: ...up of KLI 311 312 310 to operate products already registered in control pad KLR 200 20 21 Set up of KLI 311 KLI 310 to operate VELUX INTEGRA skylights 22 23 Set up of KLI 311 KLI 310 to operate VELUX...

Page 3: ...tted out of reach of children at a minimum height of 4 feet 1 2 m The control keypad must not be put into operation until it has been fitted according to these instructions Before operating ensure tha...

Page 4: ...ad is for indoor use only Installation in rooms with a high level of humidity and with hidden wiring must comply with relevant regulations contact a qualified electrician if necessary Before fixing th...

Page 5: ...ET Batteries Insert batteries as shown QUICK START Power on solar blinds at their sliding switch Power on products Power on the electrical skylights at the mains and the solar skylights at their power...

Page 6: ...aximum top or bottom position Long key pressure Product will travel only until the key is released Note If several electrical products are connected to a control unit KLC 500 only one of the products...

Page 7: ...be operated from the proposed position Fix wall bracket to wall with screws as shown Attach the wall switch to the bracket as shown If needed detach the wall switch as shown For installation of more...

Page 8: ...set up KLI 311 provided with every VELUX INTEGRA skylight The icon indicates which products it can oper ate Note KLI 311 for skylights cannot be Set up with blinds KLI 312 provided with every VELUX I...

Page 9: ...r same model as the existing KLI A Existing KLI B New KLI 1 Prepare the product for registration by pressing the Wheel buttons for 1 second The product will start running briefly back and forth 2 Pres...

Page 10: ...ts for registration by pressing each of their KLI Wheel buttons for 1 second The products will start running briefly back and forth 2 Press Rectangle button on the master wall switch KLI for 1 second...

Page 11: ...one way control 4 Tap Choose products 5 Scroll down the display and choose product type 1 Tap 2 6 Scroll down the display and tap the product to be added 1 Note The individual products can be identif...

Page 12: ...VSS VCS 2 Close the sash by pressing the button closest to the center of the skylight A 3 When the skylight is closed reset the skylight by pressing and hold ing the button closest to the center of th...

Page 13: ...ng switch on the right bottom side of motor unit Slide switch to the right and hold for 10 seconds The blind will run briefly back and forth indicating that it is ready to be registered 1B Solar power...

Page 14: ...ttings Note Reset products cannot be operated until they have been regis tered in the wall switch again 1 The control unit can be reset by removing the cover and pressing the test button for at least...

Page 15: ...cts from wall switch KLI 310 311 312 Delete reset all products from a wall switch KLI by pressing tooth wheel button for 1 sec followed by pressing rectangle button for 1 sec Now the products cannot b...

Reviews: