STOVES & CHIMNEYS
IN CASE OF SUDDEN STOP DURING OPERATION
- Please check if now is operating in the time control operation.? If so, the heater can be rest for 5min.
- Please check if now the setting temp. is less than the current temp.
- Please check if the heater is stop by pressing On/O
ff
switch by remote controller or front controller.
- Please check if the heater is stop by sleep timer function.
- Please check if the heater is stop by auto-self-checking.
AIR FLOW-OUT
In case that Electric pump so noisy and burner no ignition, main cause of the problem is ai
r fl
ow into the electric pump
and not distribute oil. If oil is all consumed without remaining in the tank, air can be
fl
ow into inside electric pump.
- The method to fl ow-out air
Operate the heater
When the electric pump operated, turn on the air out
fl
ow screw to counter-clockwise. And you wait till air
fl
ow out
and oil start to come out.
When you see oil start to come out, turn o
ff
the air out
fl
ow screw to clockwise
(In case much air inside, please repeat same way 2~3times.)
DETAIL OF BURNER STRUCTURE
- When you contact service person with a problem, please refer the below detail structure of the burner.
DAILY CHECK POINTS & ADJUSTMENT
ADJUSTMENT
FUSE(BLZND)
IGNITER
BURNER MOTER
FLAME SENSOR
(phototube)
AIR SCREW
FUEL INLET
TRANSMIT
PREVENT SENSOR
FUEL RETURN HOSE
AIR RELEASE SCREW
ELECTRONIC PUMP
FUEL LINE
AIR SUCTION HOLE
FLOWMETER
OVERHEATING SENSOR