![Veltron VHOE-90 User Manual Download Page 10](http://html1.mh-extra.com/html/veltron/vhoe-90/vhoe-90_user-manual_3991814010.webp)
- 10 -
www.veltron-heaters.com
If the following error or trouble signs are displayed on the operation panel
Displayed messages
Discription of
troubles
Items to check and required actions
E1.
No ignition
The burner is mis
fi
red
- The lack of fuel
- There is Air in the fuel tube (Air Discharge)
- Phototube pollution (Cleaning)
E2.
Phototube
(Flame sensor)
Phototube troble
Detrction of residual
fl
ame
- Unpluged Phototube (
→
plug), Phototube Trouble (
→
exchange)
- If the heater is stopped just after ignition, there is re-
sidual
fl
ame (No damage
→
Re-operation)
E3.
Temperature sensor
Temperature sensor
trouble
- Check if the temperature sensor connector is loosened.
(Firmly connect the connector if it is loosened)
E4.
Overheat sensor
Product is overheated
- Check if there are any bump signs inside the burner. (Ask the survice)
- Check if the overheat protector wire is disconnected
(Operate the heater again after connecting the wire)
E5.
Slope
Tile of heater
- Check if the heater is moved (Tilt may occur when the heater is shaken
or moved. Operate the heater again)
- Inversion switch wire is disconnected (Operate the heater again after
connectong the wire)
E6.
Lack of fuel
Lack of fuel
- Refuel (
→
Re-operation)
Hi
Temperature
is above 50 °C
- Check if the tempatature sensor is installed inside.
(Install the sensor outside)
- If the troubles E1 - E6 occur, check the causes and take the required action.
If you press the Power Button twice, you may restart the heater
If the troubles persist even after taking the actions as slanted in the below table, ask the survice
Troubles
Items to check
Required action
All lamps of operation panel
are turned o
ff
- Power failure
- Power plug is unpluged
- Fuse burns out
- Plugning
- Changing Fuse
Lamp si repeatedly turned o
ff
and turned on
- Select the time (check the lamp)
- Select the temperature
The heather is operated as no
indication of oil stu
ff
- Flowmeter wirning is unpluged
- Line connection
Something burning smells
during the initial operation
- Foreign substances are burnt inside the gasket
- To be disappeared after 1 or 2 hours
The fuel smell is unusual
- There is amell when the heater is stoped as soon
as starting
- On oil supply, spilling fuel
- Operate 15’ or more
- Remove spilled oil
Room temperature is higher
than normal one
- Check if the location of temperature sensor
(it may occur if the sensor is installed inside.)
- Fix the sensor at the correct position