杭州威狐智能科技有限公司
Hangzhou VeloFox Intelligent Technology Co,. Ltd.
文件编号
版本号
1.01
第
21
页
/
共
27
页
Power
assist level
setting
PAS=
Pedal
assistant Level
Value=
L1 to L5;
0-100%
L1-L5
Power
assist
level
corresponding
to each gear
Step=1%
Speed
magnet
numbers
Ssensor=Speed
sensor
Value= 1--12
Default value
:
1
Step=1
;
magnets
detected
by
motor
Power
assist
magnet
number
P-Sensor= PAS
sensor
Value= 1-64
Default value
:
12
Step=1;
Power
assist
magnet number
Power
Assist
Magnet
direction
Direc=
PAS
sensor direction
Value= F or R
F=Forward
R=Reversed
Signal
direction
of
sensor, can be
adjusted
corresponding
to right or left
instalation
Slow
acceleration
Slow-ACC= slow
acceleration
Value= 0-3
Default value
:
0
Number of
poles
for
power
assist
magnet
P-
Pulse=assistance
started pulse
Value= 2-63
Default Value
:
2
Step=1
Number
of
starting
magnets