10.
Error information
Display can warn bike faults. When faults are detected, error code will be shown on interface and
blink at 1Hz. When error code is shown, button functions will not be affected, meaning interfaces can
be shown normally by pressing buttons. If no button operation after 5s, the display will returns to the
error code interface.
Error code interface as shown below:
Error code information table
:
Error code
Error description
Suggest operation
"04" shown at speed
throttle doesn't turn back to zero position (stay
on the high position)
Check if the throttle
turned back
"05" shown at speed
throttle failure
Check throttle
"07" shown at speed
overvoltage protection
Check battery voltage
"08" shown at speed
failure of motor's hall signal wire
Check motor
"09" shown at speed
failure of motor's phase wire
Check motor
"11" shown at speed
failure of the motor's temperature sensor
Check controller
"12" shown at speed
failure of the current sensor
Check controller
"13" shown at speed
failure of the temperature of the battery
Check battery
"14" shown at speed
Controller temperature is too high,
and reaches the protection point
Check motor
"21" shown at speed
failure of the speed sensor
Check the install
position of the speed
sensor
"22" shown at speed
Failure of BMS communication
Change battery
"30" shown at speed
communication failure
Check connector to
controller