synchronized instant reception
12 or 24 hour display
perpetual calendar
time zone setting
alarm clock
LED backlight
wall mount or standing free
5.
Overview
Refer to the illustrations on page 2 and 3 of this manual.
A
upper pole
F
side support
B
lower pole
G
rain sensor
C
top support
H
solar panel
D
anemometer
I
sensor shelter
E
wind vane + direction sensor
J
thermo-hygrometer (under shelter)
a
MENU button
d
DOWN button (
)
b
ENTER button
e
ALARM ON/OFF button(
)
c
UP button (
)
f
HISTORY button
1
Weather forecast
10
Outdoor reception signal
2
Barometric pressure
11
Outdoor humidity
3
Barometric trend
12
Outdoor temperature
4
Date
13
Wind direction
5
Memory
14
Wind speed/gust
6
Time
15
UV index
7
Indoor humidity
16
Rainfall
8
Indoor temperature
17
Light intensity
9
transmitter low battery indicator
18
Radio Controlled Clock (RCC) indicator
6.
Setting up the stations
1.
Connect the lower pole [B] with the upper pole [A].
2.
Place the anemometer [D] on the top support [C] and fix with a bolt and nut.
3.
Place the wind vane [E] on the top support [C] and fix with a bolt and nut.
4.
Place the top support [C] on top of the upper pole [A] and fix with a bolt and nut.
5.
Mount a side support [F] on the pole [A+B] and place the rain sensor [G] on top. Secure it with a screw.
6.
Mount the second side support [F] on the pole [A+B].
7.
Place the solar panel [H] on top of the shelter [I] and secure it with a bolt and nut.
8.
Make all necessary connections:
o
Connect the anemometer [D] to the wind vane [E] phone jacket.
o
Connect the wind vane [E] to the thermo-hygrometer [J] WIND phone jacket (left).
o
Connect the rain sensor to the thermo-hygrometer [J] RAIN phone jacket (right).
9.
Insert 2 x AA rechargeable batteries (incl.) into the thermo-hygrometer [J] respecting the polarity as
indicated inside the casing. Only use rechargeable batteries!
10.
To ensure DCF reception, immediately insert 3 x AA batteries into the receiver respecting the polarity. Refer
to the section Initialization below for more information on DCF. Note that the receiver is located inside the
thermo-hygrometer
11.
Slide the thermo-hygrometer [J] into the shelter [I].
12.
Place the thermo-hygrometer [J] on top of the second side support [F] and secure it with a screw.
13.
It is strongly recommended to test the station before mounting it outdoors.
14.
Wait for the two stations to synchronize. This synchronisation may take a couple of minutes. Do not touch
any button during synchronisation. Once the synchronisation finishes, make sure that all components work
properly.