HAA9523S
v2
15/11/2013
VELLEMAN
7
Locations Code of functions
Validation
Comments
Door forced-open alarm is enabled
Door forced-open alarm is disabled
G) Output activation announcer – Installer programming
Locations Code of functions
Validation
Comments
1-second notifying beep is given to notify the person
outside to open the door when the output relay is
activated with a user code or egress button. Good for a
locking device without sound such as a magnetic lock.
Notifying beep disabled and replaced by 2 short
successful code entry beeps for valid user codes
H) User code entry mode (auto or manual) – Installer programming
Locations Code of functions
Validation
Comments
Auto entry code is selected.
key following the user
code is NOT required in code entry. The user code
MUST be set in the same digit length as the master
code in auto entry mode and the code length can be 4
to 8 digits long.
Manual entry mode is selected.
key following the
user code is required in code entry. The user codes
can be 4 to 8 digits long and they are not required to
be the same length as the master code.
NOTE:
In single user mode, no matter the selection (auto or manual mode), the master code and the user
code MUST be set as a 4-digit number.
I) Pacifier tones (keypad acknowledgement tones) – Installer programming
Locations Code of functions
Validation
Comments
Pacifier tones available on the keypad
All pacifier tones are off.
J) Allowable time to start door propped-up alarm – Installer programming
Locations Code of functions
Validation
Comments
0
No propped-up alarm
1 to 999
Allowable time from 1 to 999 seconds before door
propped-up alarm starts
K) Exit programming mode
Validation Comments
Exit programming mode and return to normal operation
7. Single User or Multi-User Mode Selection