HAA9523S
v2
15/11/2013
VELLEMAN
9
Set the system to multi-user mode with the command code 8901. The system will stay in that mode until it is
refreshed.
MASTER
CODE
Multi-user mode enabled. Wait 2-3 seconds after
pressing
until you hear confirmation beeps.
Refreshing the system
When choosing a different operation mode (see above), the system will reset and clear all values except for the
master code.
NOTE:
Make sure the user code and the master code are both 4 digits long when operating in single user mode.
8. Programming and Use of the Keypad – Operation Examples
A) Programming procedures
a.
Your
HAA9523S
is programmed from the keypad. All programmed information is stored in the non-volatile
memory.
b.
Set the keypad into programming mode first with the master code and press
to validate.
NOTE:
Use the DAP jumper to set the keypad into programming mode in case you forgot the master code.
See “
4. The DAP Jumper
”.
c.
Go to a location and program the options. See “
6. Programming the Keypad – Summary Chart
”.
d.
Program the options until all options are programmed. Repeat the programming of an option in case of a
wrong entry.
LOCATION 1
OPTION
…
LOCATION n
OPTION n
e.
Exit the programming mode with
. All input information has been saved.
B) Single user mode operation – Example
1.
Requirements
a.
Single user mode
b.
Change the factory-set master code 0000 to a personal master code 3289
c.
Set user code 1 to 8321
d.
Set user code 2 to 6854
e.
Set user code 3 to 9270
f.
Set output 1 to momentary mode, 1 second
g.
Set output 2 to start / stop mode
h.
Set output 3 to start / stop mode
i.
Set the keypad to lock itself during 15 minutes after 10 successive false codes
2.
Programming – Setting the above requirements into the keypad
Program mode with factory-set master code