DVM9915
V. 03 – 29/11/2017
11
©Velleman nv
9.6
CAPACITANCE
Do not conduct capacitance measurements on live
circuits
range
resolution
accuracy
40 nF
10 pF
± (3.0 % rdg + 10 digits)
400 nF
100 pF
± (2.5 % rdg + 5 digits)
4 µF
1 nF
40 µF
10 nF
100 µF
100 nF
± (5.0 % rdg + 10 digits)
Overload protection: F0.5 A/600 V fuse
9.7
DIODE AND CONTINUITY
Do not conduct diode or continuity measurements on
live circuits
range
description
test condition
display reads the
approximate forward
voltage of the diode
forward DC current ± 1 mA
reversed DC voltage ± 1.5 V
built-in buzzer sounds
if resistance < 30 Ω
open-circuit voltage ± 0.5 V
Overload protection: F0.5 A/600 V fuse
9.8
FREQUENCY
Do not conduct frequency measurements on live circuits
range
resolution
accuracy
10 Hz
0.01 Hz
± (0.1 % rdg + 5 digits)
100 Hz
0.1 Hz
1000 Hz
1 Hz
10 kHz
10 Hz
100 kHz
100 Hz
1000 kHz
1 kHz
10 MHz
10 kHz
Sensitivity: sine wave 0.6 V rms (10 MHz: 1.5 V rms)
Overload protection: 600 V DC or AC rms