Frequency range for AC voltage measurements : 40 - 500Hz
Response for AC voltage measurements : average, calibrated in rms of a sine wave
The 400mV range is a strictly manual range
7.2 Frequency
Function Range
Resolution
Accuracy
Frequency
Hz (10Hz - 100KHz)
50Hz
0.01Hz
500Hz
0.1Hz
5000Hz
0.001Hz
50KHz
0.01Hz
100KHz
0.1Hz
± 0.1% of rdg + 3 digits
Overload protection : 1000V DC or AC rms
7.3 Resistance
Function Range
Resolution
Accuracy
400
Ω
0.1
Ω
± 0.5% of rdg + 3 digits
4000k
Ω
1
Ω
40k
Ω
10
Ω
400k
Ω
100
Ω
4000M
Ω
1k
Ω
± 0.5% of rdg + 2 digits
Resistance
Ω
40M
Ω
10k
Ω
± 1.5% of rdg + 3 digits
Overload protection : 1000V DC or AC rms
7.4 Diode Test
Function Range
Resolution
Test
Condition
Accuracy
Diode test
1V
0.001V
forward DC current ± 1mA
reversed DC voltage ± 1.5V
± 1.0%
Overload protection : 1000V DC of AC rms
7.5 Continuity Test
Function Range
Resolution Description
Test
Condition
Continuity
400
Ω
0.1
Ω
continuity
buzzer
≤
75
Ω
open-circuit voltage : ± 0.5V
Overload protection : 1000V DC of AC rms
7.6
Capacitance
Function Range
Resolution
Accuracy
50nF
10pF
<10nF: ± [5.0% of (rdg - 50 digits) +1 digit]
± 3.0% of rdg + 10 digits)
500nF 100pF
5µF 1nF
50µF 10nF
Capacitance
100µF 100nF
± (3.0% of rdg + 5 digits)
Overload protection : 1000V DC or 1000V AC rms