PP-42A
22
30: ENGINE-IDLE
Engine idle speed. Setting range from 33,000 to 40,000 rpm in 100 rpm steps. 35,000 rpm
by default
31: ENGINE N100 %
Maximum reduced engine speed. Setting range from 100,000 to 120,000 in 100 rpm steps.
The maximum speed can be lowered or raised by the engine manufacturer, because of the
setting of engine parameters. 120,000 rpm by default
32: FUELPMP-MAX
Maximum effective voltage of the fuel pump. Setting range from 2,4 to 10,7 V in 0.1 V
steps.
9.6 V by default
33: UP
The acceleration ramp from IDLE to ENGINE N100% speed. Setting range from 4 to 10 s
in 0.1 s steps. 4,0 s by default.
34: DOWN
The deceleration ramp from ENGINE N100% to IDLE. etting range from 4 to 10 s in 0.1 s
steps. 4,0 s by default.
35: EGT-MAX
Maximal regulated temperature of exhaust gases. Setting range from 600
to 880 °C in
steps of
5 °C. We recommend to not change the setting.
By default 880°C.
36: START-EGT-OFF
Maximum exhaust gas temperature during start. If 950
°C is exceeded for a period longer
than 3 s, the engine switches off., Cannot be changed.
37: RUN-EGT-OFF
Maximum exhaust gas temperature during run. If 900
°C is exceeded for a period longer
than 3 s, the engine switches off. Cannot be changed.