Appendix C — Filter Manager Error/Status Codes
117
Filter Manager Error/Status Codes
-48
Unable to read mark-in from tape deck.
Check COM port connec-
tions, Check to see that VTR
is in remote mode, etc.
-49
Unable to recognize microcode type in looking
up VTR adjustment in Registry.
-50
Error initializing pin that connects IBMVideo to
Mux component.
Check swap space on C:\
drive. Make sure mux was
shut down properly last
time (that CVProServer and
MemMgrServer were not
left running).
-51
Attempted to initialize a video component that
was already initialized.
Try resetting or quitting appli-
cation. Make sure no other
instances of the encoder are
running simultaneously.
Be sure to terminate
CVProServer and
MemMgrServer before
restarting.
-52
Attempted to cue a video component that was
already cued.
Try resetting or quitting appli-
cation. Make sure no other
instances of the encoder are
running simultaneously.
Be sure to terminate
CVProServer and
MemMgrServer before
restarting.
-52
V_INIT
(Encoder chip error code)
An error occurred while
attempting to initialize the
video board. Run diags.
-53
Attempted to cue a video component that was
already playing.
Terminate last encode (or
wait for it to finish) before
starting next encode.
Filter Manager Error/Status Codes (Continued)
Error Code
Meaning
Comments
Table C-1. Filter Manager Error/Status Codes (Continued)