10
3 Product description
VEGASWING 63 • Two-wire 8/16 mA
29232-EN-180704
You can find information in the operating instructions manual of the
electronics module.
The lock fitting is used for for infinite locking with tube extension.
The following lock fittings are available:
•
ARV-SG63.1 - unpressurized
•
ARV-SG63.2 - up to 16 bar
•
ARV-SG63.3 - up to 64 bar
The wetted parts of the lock fitting can be either of steel (316L) or
Alloy C22 (2.4602).
Lock fittings cannot be used in coated tube extensions.
You can find additional information in the operating instructions manu-
als of the lock fittings.
For connecting the sensors with a separator to voltage supply or sig-
nal processing, the sensors are also available with plug connectors.
The following plug connectors are available:
•
M12 x 1
•
ISO 4400
•
Harting HAN 7D
•
Harting HAN 8D
•
Amphenol-Tuchel
Lock fitting
Plug connector