34
10 Supplement
VEGAPULS WL S 61 • 4 … 20 mA
54408-01-190806
10 Supplement
10.1 Technical data
General data
Materials, wetted parts
Ʋ Antenna
PP
Materials, non-wetted parts
Ʋ Housing
Plastic PBT (Polyester)
Ʋ Connection cable
PUR
Ʋ Type label support on cable
PE hard
Thread on the housing
G1½ cylindrical (ISO 228 T1)
Weight
Ʋ Instrument
0.7 kg (1.543 lbs)
Ʋ Connection cable
0.1 kg/m (0.07 lbs/ft)
Input variable
Measured variable
The measured quantity is the distance between the lo-
wer antenna side and the product surface. The reference
plane for the measurement is also the lower antenna
side.
2
3
1
Abb. 24: Data of the input variable
1 Reference plane
2 Sensor length
3 Max. measuring range
Max. measuring range
8 m (26.25 ft)
Output variable
Output signal
4 … 20 mA
Range of the output signal
3.8 … 20.5 mA (default setting)
Signal resolution
0.3 µA
Resolution, digital
1 mm (0.039 in)
Fault signal, current output (adjustable) mA-value unchanged 20.5 mA, 22 mA, < 3.6 mA
Max. output current
22 mA
Load
See load resistance under Power supply
Starting current
≤ 3.6 mA; ≤ 10 mA for 5 ms after switching on