background image

Quick setup guide

Radar sensor for continuous level 

measurement of water and wastewater

VEGAPULS WL 61

4 … 20 mA/HART two-wire

Document ID: 47095

Summary of Contents for VEGAPULS WL 61

Page 1: ...Quick setup guide Radar sensor for continuous level measurement of water and wastewater VEGAPULS WL 61 4 20 mA HART two wire Document ID 47095...

Page 2: ...p 11 4 Connecting to power supply 4 1 Wiring plan 12 5 Set up with VEGADIS 82 5 1 Principle of operation and connection 13 5 2 Adjustment volume 13 5 3 Setup steps 14 6 Setup with PACTware 6 1 Connect...

Page 3: ...art instrument complying with all prevailing regulations and guidelines The instrument must only be operated in a technically flawless and reliable condition The operator is responsible for the troub...

Page 4: ...is approved for unrestricted use inside and outside of closed ves sels in countries of the EU and EFTA that have implemented this standard Austria Belgium Bulgaria Germany Denmark Estonia France Greec...

Page 5: ...the following two conditions this device may not cause interference and this device must accept any interference including interference that may cause undesired operation of the device Le pr sent app...

Page 6: ...12 Data Matrix Code for Smartphone App 13 Symbol of the device protection class 14 ID numbers instrument documentation 15 Reminder to observe the instrument documentation 16 Notified authority for CE...

Page 7: ...1 4 20 mA HART two wire 47095 EN 140801 Download the smartphone app VEGA Tools from the Apple App Store or the Google Play Store Scan the Data Matrix code on the type label of the instrument or Enter...

Page 8: ...In order to avoid faulty measured values make sure that the sensor does not oscillate 200 mm 7 87 Fig 2 Mounting via a straining clamp For a rigid mounting a mounting bracket with opening for thread G...

Page 9: ...wall or bracket It is available in the following versions Length 300 mm for ceiling mounting Length 170 mm for wall mounting The instrument is normally mounted with a strap vertically on the ceiling...

Page 10: ...or obliquely 200 mm 7 87 Fig 6 Wall mounting via the mounting strap with length 170 mm Fig 7 Wall mounting with inclined wall via the mounting strap with length 300 mm For mounting the instrument on a...

Page 11: ...eparations mounting strap The optional mounting strap is supplied unassembled It must be screwed to the sensor before setup with the attached screws Max torque see chapter Technical data Required tool...

Page 12: ...mA HART two wire 47095 EN 140801 4 Connecting to power supply 4 1 Wiring plan 1 2 Fig 9 Wire assignment in permanently connected connection cable 1 brown and blue to power supply or to the processing...

Page 13: ...external energy is not required 4 5 3 1 2 Fig 10 Connection of the VEGADIS 82 to the sensor adjustment via the dis play and adjustment module 1 Voltage supply Signal output sensor 2 VEGADIS 82 3 Disp...

Page 14: ...WL 61 4 20 mA HART two wire 47095 EN 140801 Info Instrument type and serial number 5 3 Setup steps You can find a detailed description of the setup steps for VE GAPULS WL 61 in the operating instruct...

Page 15: ...C Voltage supply 5 Interface adapter VEGACONNECT Note With power supply units with integrated HART resistance internal resistance approx 250 an additional external resistance is not necessary This app...

Page 16: ...e DTMs are compiled in a DTM Collec tion The DTMs can also be integrated into other frame applications according to FDT standard Note To ensure that all instrument functions are supported you should a...

Page 17: ...y Saving printing the project as well as import export functions are also part of the standard version In the full version there is also an extended print function for complete project documentation a...

Page 18: ...ng radius 25 mm 0 984 in with 25 C 77 F Diameter approx 8 mm 0 315 in Wire isolating and cable cover PUR Colour standard Black Colour Ex version Blue Fire protection classification UL94 V0 Voltage sup...

Page 19: ...19 Notes VEGAPULS WL 61 4 20 mA HART two wire 47095 EN 140801...

Page 20: ...of delivery application practical use and operat ing conditions of the sensors and processing systems correspond to the information available at the time of printing Subject to change without prior n...

Reviews: