8
4 Connecting to power supply
VEGAPULS 6X • Two-wire 4 … 20 mA/HART
66376-EN-220111
4 Connecting to power supply
4.1 Connection steps voltage supply
The connection of the voltage supply is made via spring-loaded ter-
minals. A small screwdriver is required to open the terminals. Solid as
well as flexible cores without cable end sleeves can be used.
Proceed as follows:
1. Unscrew the housing lid
2. Loosen compression nut of the cable gland and remove blind
plug
3. Remove approx. 10 cm (4 in) of the cable mantle, strip approx.
1 cm (0.4 in) of insulation from the ends of the individual wires
4. Insert the cable into the cable gland through the cable entry
Fig. 6: Connection steps 4 and 5
5. Lift the opening levers of the terminals with a screwdriver
6. Insert the wire ends into the open terminals according to the wir-
ing plan
7. Press down the opening levers of the terminals, you will hear the
terminal spring closing
8. Check the hold of the wires in the terminals by lightly pulling on
them
9. Connect the shielding to the internal ground terminal, connect the
external ground terminal to potential equalisation
10. Tighten the compression nut of the cable entry gland. The seal
ring must completely encircle the cable
11. Screw the housing lid back on
The electrical connection is finished.
Connection technology
Connection procedure