5
I
nsert the cable into the sensor through the cable entry
F
ig
.
18
:
C
onnection steps
5
and
6
6
I
nsert the wire ends into the terminals according to the wiring plan
I
nformation
:
S
olid cores as well as
fl
exible cores with cable end sleeves are
inserted directly into the terminal openings
.
I
n case of
fl
exible cores
without end sleeves
,
press the terminal head with a small screwdriver
;
the terminal opening is freed
.
W
hen the screwdriver is released
,
the
terminal closes again
.
7
C
heck the hold of the wires in the terminals by lightly pulling on
them
8
C
onnect the screen to the internal ground terminal
,
connect the
outer ground terminal to potential equalisation
9
T
ighten the compression nut of the cable entry
.
T
he seal ring must
completely encircle the cable
10
S
crew the housing cover on
T
he electrical connection is
fi
nished
.
I
nformation
:
T
he terminal block is pluggable and can be removed from the
electronics
.
F
or this purpose
,
lift the terminal block with a small
screwdriver and pull it out
.
W
hen inserting the terminal block again
,
you should hear it snap in
.
VEGAPULS
62
•
4
…
20
m
A
/
HART
two
-
wire
27
5
C
onnecting to power supply
36503
-
EN
-
100607