47
10 Supplement
VEGACAL 62 • Profibus PA
30025-EN-160331
10 Supplement
10.1 Technical data
General data
Material 316L corresponds to 1.4404 or 1.4435
Materials, wetted parts
Ʋ Process fitting - thread
316L
Ʋ Process fitting - flange
316L
Ʋ Process seal
Klingersil C-4400
Ʋ insulation (partly insulated)
PTFE, PEEK
Ʋ Electrode (rod partly PTFE insulated:
ø 12 mm/0.472 in)
316L
Ʋ Electrode (rod partly PEEK insulated:
ø 12 mm/0.472 in)
316L
Materials, non-wetted parts
Ʋ Plastic housing
plastic PBT (Polyester)
Ʋ Aluminium die-casting housing
Aluminium die-casting AlSi10Mg, powder-coated - basis:
Polyester
Ʋ Stainless steel housing - precision
casting
316L
Ʋ Stainless steel housing, electropol-
ished
316L
Ʋ Seal between housing and housing lid NBR (stainless steel housing, precision casting), silicone
(aluminium/plastic housing; stainless steel housing,
electropolished)
Ʋ Ground terminal
316L
Ʋ Cable gland
PA, stainless steel, brass
Ʋ Sealing, cable gland
NBR
Ʋ Blind plug, cable gland
PA
Process fittings
Ʋ Pipe thread, cylindrical (DIN 3852-A) G½, G¾, G1, G1½
Ʋ American pipe thread, conical
(ASME B1.20.1)
½ NPT, ¾ NPT, 1 NPT, 1½ NPT
Ʋ Flanges
DIN from DN 25, ASME from 1"
Weight
Ʋ Instrument weight (depending on
process fitting)
0.8 … 4 kg (0.18 … 8.82 lbs)
Ʋ Rod weight: ø 12 mm (0.472 in)
900 g/m (9.9 oz/ft)
Sensor length (L)
0.1 … 6 m (0.328 … 19.69 ft)
Max. lateral load
10 Nm (7.4 lbf ft)
Max. torque (process fitting - thread)
100 Nm (73 lbf ft)
Torque for NPT cable glands and Conduit tubes
Ʋ Plastic housing
max. 10 Nm (7.376 lbf ft)