![Vega VEGABAR 82 Operating Instructions Manual Download Page 65](http://html1.mh-extra.com/html/vega/vegabar-82/vegabar-82_operating-instructions-manual_859602065.webp)
65
11 Supplement
VEGABAR 82 • Profibus PA
45031-EN-220624
Ʋ Pressure value
-20 … 120 %
Zero/Span adjustment:
Ʋ Zero
-20 … +95 %
Ʋ Span
-120 … +120 %
Ʋ Difference between zero and span
max. 120 % of the nominal range
Max. permissible Turn Down
Unlimited (recommended 20 : 1)
Switch-on phase
Start-up time with operating voltage U
B
Ʋ ≥ 12 V DC
≤ 9 s
Ʋ < 12 V DC
≤ 22 s
Output variable
Output signal
digital output signal, Profibus protocol
Transmission rate
31.25 Kbit/s
Instrument address
126 (default setting)
Damping (63 % of the input variable)
0 … 999 s, adjustable
Profibus PA profile
3.02
Number of FBs with AI (function blocks
with analogue input)
3
Default values
Ʋ 1. FB
Primary Value (pressure linearized in %)
Ʋ 2. FB
Secondary Value 1 (pressure)
Ʋ 3. FB
Secondary Value 2 (pressure in %)
Current value
Ʋ Non-Ex, Ex-ia and Ex-d instruments
12 mA, ±0.5 mA
Dynamic behaviour output
Dynamic characteristics depending on medium and temperature