6 Set up with the display and adjustment module
VEGABAR 82 • Profibus PA
45031-EN-220624
In this menu item, the date of factory calibration of the sensor as well
as the date of the last change of sensor parameters are displayed via
the display and adjustment module or via the PC.
In this menu item, the Profibus ident number of the sensor is dis-
played.
In this menu item, the features of the sensor such as approval, pro-
cess fitting, seal, measuring range, electronics, housing and others
are displayed.
6.6 Menu overview
The following tables show the adjustment menu of the instrument.
Depending on the instrument version or application, all menu items
may not be available or some may be differently assigned.
Setup
Menu item
Parameter
Default value
Sensor address
126
Measurement loop name
19 alphanumeric characters/special
characters
Sensor
Application
Level, process pressure
Level
Secondary Device for electronic differen-
tial pressure
1)
Deactivated
Units
Adjustment unit (m, bar, Pa, psi … user-
defined)
mbar (with nominal measuring range
≤ 400 mbar)
bar (with nominal measuring ranges
≥ 1 bar)
Temperature unit (°C, °F)
°C
Factory calibration date
Profibus ident number
Sensor characteristics
1)
Parameter only active if the instrument is connected to the Secondary sensor