52
11 Supplement
VEGABAR 81 • 4
… 20 mA
45025-EN-140228
Input variable - Piezoresistive/Thin film measuring cell
Nominal measuring ranges and overload capability in bar/kPa
The specifications are only an overview and refer to the measuring cell. Limitations due to the
material and version of the process fitting as well as the selected pressure type are possible. The
specifications on the nameplate apply.
Nominal range
Overload capacity, max.
pressure
Overload capacity, min. pres-
sure
Gauge pressure
0 …
+0.4
bar/0 …
+40
kPa
+2 bar/+200 kPa
-1
bar/-100
kPa
0 … +1 bar/0 … +100 kPa
+5
bar/+500
kPa
-1
bar/-100
kPa
0 …
+2.5
bar/0 …
+250
kPa
+10 bar/+1000 kPa
-1
bar/-100
kPa
0 … +10 bar/0 … +1000 kPa
+35
bar/+3500
kPa
-1
bar/-100
kPa
0 …
+25
bar/0 …
+2500
kPa
+50
bar/+5000
kPa
-1
bar/-100
kPa
0 …
+40
bar/0 …
+4000
kPa
+80 bar/+8000 kPa
-1
bar/-100
kPa
0 … +100 bar/0 … +10
MPa
+200 bar/+20
MPa
-1
bar/-100
kPa
0 …
+250
bar/0 …
+25
MPa
+500
bar/+50
MPa
-1
bar/-100
kPa
0 … +600 bar/0 … +60 kPa
+1200 bar/+120
MPa
-1
bar/-100
kPa
0 … +1000 bar/0 … +100
MPa
+1500
bar/+150
MPa
-1
bar/-100
kPa
-1
… 0
bar/-100
… 0 kPa
+5
bar/+500
kPa
-1
bar/-100
kPa
-1
…
+1.5
bar/-100
…
+150
kPa
+10 bar/+1000 kPa
-1
bar/-100
kPa
-1
… +10
bar/-100
… +1000 kPa
+80 bar/+8000 kPa
-1
bar/-100
kPa
-1
…
+25
bar/-100
…
+2500
kPa
+80 bar/+8000 kPa
-1
bar/-100
kPa
-1
…
+40
bar/-100
…
+4000
kPa
+80 bar/+8000 kPa
-1
bar/-100
kPa
-0.2
… +0.2
bar/-20
… +20 kPa
+2 bar/+200 kPa
-1
bar/-100
kPa
-0.5
…
+0.5
bar/-50
…
+50
kPa
+5
bar/+500
kPa
-1
bar/-100
kPa
Absolute pressure
0 … 1 bar/0 … 100 kPa
5
bar/+500
kPa
0 bar abs.
0 …
2.5
bar/0 …
250
kPa
10 bar/+1000 kPa
0 bar abs.
0 … 10 bar/0 … 1000 kPa
35
bar/+3500
kPa
0 bar abs.
0 …
25
bar/0 …
2500
kPa
50
bar/+5000
kPa
0 bar abs.
0 …
40
bar/0 …
4000
kPa
80 bar/8000 kPa
0 bar abs.
Nominal measuring ranges and overload capacity in psi
The specifications are only an overview and refer to the measuring cell. Limitations due to the
material and version of the process fitting as well as the selected pressure type are possible. The
specifications on the nameplate apply.
Nominal range
Overload capacity, max.
pressure
Overload capacity, min. pres-
sure
Gauge pressure
0 …
+5
psig
+25
psig
-14.5
psig
0 …
+15
psig
+75
psig
-14.5
psig