à
S
end sensor for repair
?
E
030
l
sensor in boot phase
l
I
nvalid measured value
à
C
heck sensor parameter adjustment
?
E
034
l
EEPROM
defective
à
C
arry out a reset
à
S
end instrument for repair
?
E
035
l
EEPROM CRC
error
à
C
arry out a reset
à
S
end instrument for repair
?
E
036
l
I
nstrument software not executable
(
during software
update or after failed update
)
à
W
ait until software update is
fi
nished
à
C
arry out another software update
?
E
042
l
H
ardware error with selfcheck
à
S
end instrument for repair
?
E
053
l
S
ensor measuring range not read correctly
à
HART
communication error
:
C
heck sensor cable and
screening
?
E
086
l
E
rror communication hardware
(
initialisation of the
radio module failed
)
à
I
nitialisation is carried out automatically
.
I
f the error
exists permanently
,
send instrument for repair
M
aintenance and fault recti
fi
cation
34
PLICSRADIO T
61
-
wireless emitting unit
(
single channel
)
32865
-
EN
-
070801