application must make sure that the network server is running at the current data rate at which
the device is running, allowing you to send larger packets. The table below shows the
maximum package sizes for different data rates.
Data rate
Spread factor
Maximum packet size
DR0
SF12
51 bytes
DR1
SF11
51 bytes
DR2
SF10
51 bytes
DR3
SF9
115 bytes
DR4
SF8
222 bytes
DR5
SF7
222 bytes
5.
Output off command
Size in bytes
Field description
1 byte
Packet type, this packet == 5
1 byte
Output no. (1 - 2)
6.
Packet with request of settings
–
sent by application on LoRaWAN port 3
Size in bytes
Field description
1 byte
Packet type, this packet == 1
Answering that packet, the device sent the packet with settings.
7.
Packet with settings is identical to such packet from device
Size in bytes
Field description
Data type
1 byte
Packet type, this packet == 0
2 bytes
ID of parameter
uint16
1 byte
Data length (len)
uint8
len bytes
Parameter value
-----
2 bytes
ID of parameter
uint16
1 byte
Data length (len)
uint8
len bytes
Parameter value
-----
…
…
…
2 bytes
ID of parameter
uint16
1 byte
Data length (len)
uint8
len bytes
Parameter value
-----
The package with settings sent to the device may not contain all the settings supported
by the device, but only the part that needs to be changed.