Audible Alarm:
On or Off. Provides an audible indication when alarm or error condition is recorded.
-
APS Protocol:
Linear or Ring architectures are selectable. This determines how the APS bytes (K1/K2) are decoded in the
SONET Overhead Analyzer or how they are generated in the SONET Overhead Generator. It also determines how the APS
measurement will be made.
- SDH/SONET/:
SDH or SONET modes are selectable options available.
- Result on start:
On or Off. Provides an automatic move to result screen when it start..
-
Auto Sav
e: The automatic save results file, tab the Auto save set to "ON" will automatically saved the results file.
-
Measurement Clock Source
: Internal Clock or Tx Clock Source; the measurement synchronized to the Tx Clock.
7.6.4 Auto-Config
The Auto-configuration function is described below.
The
“Auto-Config”
function automatically sets the receiver of the TX150. A search for SONET and PDH/DSn signals at both
the electrical or optical inputs is performed to determine the signal structure. For electrical signals, both Terminated and PMP
TX150 e-Manual D07-00-023 Rev A02
Page 31 of 107