 Installing The TLS-450PLUS Console

Connecting The Power Wires To The Console

4. Next strip the ends of the power wires brought into the console. Referring to Figure 5 and to the locations 

printed where the power connector attaches to the console, attach the L1, panel ground and neutral wires 
(#14 AWG) to the connector block.

5. Next, attach the barrier ground (sized as shown in Figure 5) to the grounding clamp. 

Figure 5.  Wiring AC Power To The TLS-450PLUS Console

6. Plug in the power connector and route the wires so that the cover plate will conceal them when installed.

7. Replace the power connector cover plate using both screws and close the bay door.

8. Reconnect the communication wires to the appropriate comm cards. Wires which are not used on the TLS-

450PLUS should be pulled back into the wiring trough. If necessary, seal up the power trough. 

9. Return to the panel, remove the lock-out/tag-out device and label the breaker with the supplied self-adhesive 

label. Re-energize the circuit and start up the unit.

L1
N
L2

L1
G
L2

(To 240 Vac 

breaker in

power panel)

240 Vac Power Input

120 Vac Power Input

L1 (BLK)

N/L2 (WHT)

N/L2 (BLK)

G (GRN)

Barrier (G/Y)

L1 (RED)

(To 120 Vac 

breaker in

power panel)

Attach barrier wire
to grounding clamp

Power connector
conduit entry

•  Barrier ground wire requirements:
 

- For UL/cUL approved systems, use a 12 AWG barrier ground wire

 

- For ATEX/IECEx approved systems, use a 4 sq. mm barrier ground wire

•  Use an ohmmeter to check the electrical resistance between the console’s metal case and the power panel’s earthing
 

ground wire connection at the ‘known good ground’. It should read less than 1 ohm.

•  Connect the power supply wires in the power panel to a separate dedicated circuit.
•  Electrical rating of power input - 120 or 240 Vac, 50/60 Hz, 2 A maximum.
•  See Figure 1 for locations of power conduit knockouts into the console. Power wiring must enter the console
 

through designated knockouts.

POWER WIRING NOTES:

To grounding 
terminal bar
in power panel 

G (GRN)

Barrier (G/Y)

To grounding 
terminal bar
in power panel 

Attach barrier wire
to grounding clamp

Power connector
conduit entry

Summary of Contents for TLS-350l

Page 1: ...Manual No 577014 074 Revision A Upgrade Instructions TLS 350 To TLS 450PLUS Console...

Page 2: ...ur Terms and Conditions VEEDER ROOT S PREFERRED CARRIER 1 Contact Veeder Root Customer Service at 800 873 3313 with the specific part numbers and quantities that were missing or received damaged 2 Fax...

Page 3: ...ions Against Static Electricity 5 Comm Module Slots And Configurable ports 5 Connecting The Power Wires To The Console 8 Initial Startup Procedure For Sites Without Wireless 2 devices 10 For Sites Wit...

Page 4: ...ation checkout startup programming system tests troubleshooting service techniques and operations training on the designated system Wireless 2 Tall Tank Warranty Registrations may only be submitted by...

Page 5: ...AC power supply wires at the breaker until all devices are connected 2 Attach conduit from the power panel to the console s Power Area knockouts only 3 Comply with all applicable codes including the N...

Page 6: ...ally safe wires are labeled and their polarity if applicable noted before removing them Verify all non intrinsically wiring connections are labeled before removing them 5 Unplug the high and low volta...

Page 7: ...ight Connecting Wiring To Console Modules Refer to the appropriate Control Drawing on page 2 to identify modules that can be installed in the console and the designated devices that can be connected t...

Page 8: ...ts 1 3 are available for user selectable Comm modules Figure 3 Slots 4 and 5 are fixed and can not be changed see Figure 4 2 Important to avoid attaching a Comm cable to a non configurable NC port ide...

Page 9: ...6 18 35 BOTTOM VIEW tlsng dim eps Mounting flanges w 1 4 x 3 8 slotted hole typ 4 places 3 1 8 1 2 TYP 5 925 0 65 4 5 8 3 1 8 3 1 8 3 1 8 TOP VIEW Conduit entries to Module bay 3 4 1 I P S knockouts t...

Page 10: ...3 2 1 4 4 5 L1 G N L2 Comm module clamp securing screw Slots 1 3 Selectable Comm Modules see Figure 3 Slots 4 and 5 Fixed Comm Modules see Figure 4 Slots 1 4 Any combination of USM I O MDIM or LVDIM...

Page 11: ...The console is prepunched for conduit This should be large enough since the only wires going through this conduit will be for L1 neutral panel ground and earth ground and possibly 1 relay Refer to man...

Page 12: ...elf adhesive label Re energize the circuit and start up the unit L1 N L2 L1 G L2 To 240 Vac breaker in power panel 240 Vac Power Input 120 Vac Power Input L1 BLK N L2 WHT N L2 BLK G GRN Barrier G Y L1...

Page 13: ...LS 450PLUS and wait 5 minutes until the console s Discover Mode is complete 2 Setup the TLS 450PLUS FOR SITES WITH WIRELESS 2 DEVICES 1 Power up all wireless devices 2 Power up the TLS RF console and...