background image

ii

Notice

Veeder-Root makes no warranty of any kind with regard to this publication, including, but not limited to, the implied warranties of
merchantability and fitness for a particular purpose.

Veeder-Root shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing,
performance, or use of this publication.

Veeder-Root reserves the right to change system options or features, or the information contained in this publication.

This publication contains proprietary information which is protected by copyright. All rights reserved. No part of this publication may be
photocopied, reproduced, or translated to another language without the prior written consent of Veeder-Root.

Contact TLS Systems Technical Support for additional troubleshooting information at 800-323-1799.

DAMAGE CLAIMS / LOST EQUIPMENT

Thoroughly examine all components and units as soon as they are received. If any cartons are damaged or missing, write a complete
and detailed description of the damage or shortage on the face of the freight bill. The carrier's agent must verify the inspection and sign
the description. Refuse only the damaged product, not the entire shipment.

Veeder-Root must be notified of any damages and/or shortages within 30 days of receipt of the shipment, as stated in our Terms and
Conditions. 

VEEDER-ROOT’S PREFERRED CARRIER

1.

Contact Veeder-Root Customer Service at 800-873-3313 with the specific part numbers and quantities that were missing or
received damaged.

2.

 Fax signed Bill of Lading (BOL) to Veeder-Root Customer Service at 800-234-5350.

3.

Veeder-Root will file the claim with the carrier and replace the damaged/missing product at no charge to the customer. Customer
Service will work with production facility to have the replacement product shipped as soon as possible.

CUSTOMER’S PREFERRED CARRIER

1.

It is the customer’s responsibility to file a claim with their carrier.

2.

Customer may submit a replacement purchase order. Customer is responsible for all charges and freight associated with
replacement order. Customer Service will work with production facility to have the replacement product shipped as soon as
possible.

3.

If “lost” equipment is delivered at a later date and is not needed, Veeder-Root will allow a Return to Stock without a restocking fee.

4.

Veeder-Root will NOT be responsible for any compensation when a customer chooses their own carrier. 

RETURN SHIPPING

For the parts return procedure, please follow the appropriate instructions in the "General Returned Goods Policy” pages in the
"Policies and Literature" section of the Veeder-Root 

North American Environmental Products

 price list. Veeder-Root will not accept

any return product without a Return Goods Authorization (RGA) number clearly printed on the outside of the package.

 ©Veeder-Root 2014. All rights reserved

.

Summary of Contents for TLS-350l

Page 1: ...Manual No 577014 074 Revision A Upgrade Instructions TLS 350 To TLS 450PLUS Console...

Page 2: ...ur Terms and Conditions VEEDER ROOT S PREFERRED CARRIER 1 Contact Veeder Root Customer Service at 800 873 3313 with the specific part numbers and quantities that were missing or received damaged 2 Fax...

Page 3: ...ions Against Static Electricity 5 Comm Module Slots And Configurable ports 5 Connecting The Power Wires To The Console 8 Initial Startup Procedure For Sites Without Wireless 2 devices 10 For Sites Wit...

Page 4: ...ation checkout startup programming system tests troubleshooting service techniques and operations training on the designated system Wireless 2 Tall Tank Warranty Registrations may only be submitted by...

Page 5: ...AC power supply wires at the breaker until all devices are connected 2 Attach conduit from the power panel to the console s Power Area knockouts only 3 Comply with all applicable codes including the N...

Page 6: ...ally safe wires are labeled and their polarity if applicable noted before removing them Verify all non intrinsically wiring connections are labeled before removing them 5 Unplug the high and low volta...

Page 7: ...ight Connecting Wiring To Console Modules Refer to the appropriate Control Drawing on page 2 to identify modules that can be installed in the console and the designated devices that can be connected t...

Page 8: ...ts 1 3 are available for user selectable Comm modules Figure 3 Slots 4 and 5 are fixed and can not be changed see Figure 4 2 Important to avoid attaching a Comm cable to a non configurable NC port ide...

Page 9: ...6 18 35 BOTTOM VIEW tlsng dim eps Mounting flanges w 1 4 x 3 8 slotted hole typ 4 places 3 1 8 1 2 TYP 5 925 0 65 4 5 8 3 1 8 3 1 8 3 1 8 TOP VIEW Conduit entries to Module bay 3 4 1 I P S knockouts t...

Page 10: ...3 2 1 4 4 5 L1 G N L2 Comm module clamp securing screw Slots 1 3 Selectable Comm Modules see Figure 3 Slots 4 and 5 Fixed Comm Modules see Figure 4 Slots 1 4 Any combination of USM I O MDIM or LVDIM...

Page 11: ...The console is prepunched for conduit This should be large enough since the only wires going through this conduit will be for L1 neutral panel ground and earth ground and possibly 1 relay Refer to man...

Page 12: ...elf adhesive label Re energize the circuit and start up the unit L1 N L2 L1 G L2 To 240 Vac breaker in power panel 240 Vac Power Input 120 Vac Power Input L1 BLK N L2 WHT N L2 BLK G GRN Barrier G Y L1...

Page 13: ...LS 450PLUS and wait 5 minutes until the console s Discover Mode is complete 2 Setup the TLS 450PLUS FOR SITES WITH WIRELESS 2 DEVICES 1 Power up all wireless devices 2 Power up the TLS RF console and...

Page 14: ...For technical support sales or other assistance please visit www veeder com...

Reviews: