Console Wiring Inputs
National Electrical Code Compliance
8
Low Voltage
Inputs
1 Low Voltage Input:
Maximum contact closure circuit ratings 12 Vdc, 0.015A
Class I wiring is required for these 12 volt closure circuits.
Legend
Pin
Input
Dry Contact Switch
1
RTN
2
12V
For Future Use
3
PWR STAT
4
PWR INT
RS-2
3
2 Ports
2 optically isolated serial ports standard, labeled SERIAL 1 supporting full handshaking and SERIAL 2.
The RS-232 D-connector is a panel mount, 9-pin female type, wired in a Data Terminal Equipment (DTE) configura-
tion. For example, any RS-232 port in any TLS consoles is also a DTE, therefore, a Null Cable is needed in order for
communication to happen between the two consoles.
A Data Communication Equipment (DCE) device such as a modem may be connected directly to the interface using
a straight-through cable (modem support may not be available on all ATGs). Handshake signals in the system are
configurable.
RS-232 signals are wired to the female D-connectors as follows:
SERIAL1 (Full Handshake)
Pin
Signal
Pin
Signal
1
Data Carrier
Detect
6
Data Set Ready
2
Received
Data
7
Request to Send
3
Transmitted
Data
8
Clear to Send
4
Data Termi-
nal Ready
9
Ring Indicator
5
Signal
Ground
SERIAL 2
Pin
Signal
Pin
Signal
1
6
2
Received
Data
7
3
Transmitted
Data
8
4
9
5
Signal
Ground
Table 1. TLS4 Wiring Inputs
Connector
Description
RTN
PWR STAT
PWR INT
12V
022 10
022-6
5
4
3
2
1
9
8
7
6
022-6
5
4
3
2
1
9
8
7
6