weighing mode press 

 key.  To clear the current account in order to create a new one press  

 key. To subtract the last added “Price to pay” from the current account press 

 key. 

 

4.8. Using Price Look-Up (PLU numbers)

 – By pressing the 

 key, the scale enters in 

select PLU number mode and the last entered article (item) is displayed.  A new PLU number can be 

entered directly from the keypad and then confirmed by pressing 

 key. After selecting the new 

article, its unit price is shown in “Price, euro/kg” line on the display. To clear the price of the article 

press 

 key. 

 

4.9. Label printing

 – After measuring the load on the scale and entering its PLU number, a 

label can be printed via a connected label printer by pressing 

 key. All the data from the current 

measure (weight, price, barcode, name of the article, durability and etc.) is sent to the printer and a 
label is printed out in accordance to a programmed form.  

 
5. Work with the menus and service mode functions of the scale 
 

To enter the main menu of the scale, press 

 key. To enter a submenu and confirm the selected 

setting/parameter, press 

 key. Moving between the different submenus and parameters is done 

with  

 and 

 keys. 

 

 
Entering the submenu Bat, the display shows 
voltage of the built-in rechargeable battery in Volts. 
 

 

 
Entering the submenu Fine, the display shows the 
measured weight in high resolution in grams. In this 
mode the price-computing, label printing and all 
data transmission over the serial interfaces is 
forbidden. 
 

 

 
In this submenu, a protocol for connection with the 
first serial interface is selected. The sustained 
protocols are: 
OFF – the port if turned off; 
Pr1 – Protocol VEDIA with uninterrupted weight 
transmission; 
Pr2 – Protocol VEDIA with a single time weight 
transmission after external command or pressing 

key  key

Pr3 – Protocol for Datecs cash-registers; 
Pr4 – Protocol for connection with a PC and cash-
registers produced by “Zavod Electronica”, 
“ZEKA”, “Orgtechnika”; 
Pr5 – Protocol for “ZIT”cash-registers.  
After each change of the protocol, the scale is 
restarted. 
 

 

 
In this submenu, a protocol for connection with 

8

Summary of Contents for VDI 15/30

Page 1: ...User Manual ELECTRONIC SCALE The product is designed and produced in the terms of applied Quality Management System ISO 9001 2008...

Page 2: ...ion of conformity In case of missing please immediately turn to the distributor you bought the scale from or directly to VEDICOM Ltd II Brief Introduction Electronic scales VEDIA are non automatic wei...

Page 3: ...III Technical characteristics Model Max capacity Division Platform size mm No of Load Cells Built in battery VDI 3 6 3 6kg 1g 2g 350 450 1 yes VDI 6 15 6 15kg 2g 5g 350 450 1 yes VDI 6 30 6 30kg 2g 10...

Page 4: ...IV Layout of the scale and its components Keyboard Display...

Page 5: ...he load cell permanently Avoid operating it on vibrating surfaces and close to sources of strong electro magnetic fields 2 Keep the scale in airy and dry place avoid leaving it under direct sunlight 3...

Page 6: ...of the tare with and the indicator tare lights up By pressing TARE key the scale is zeroed again 4 5 Weight measuring The item to be weighted is placed on the scale pan the first line of the display...

Page 7: ...e mode functions of the scale To enter the main menu of the scale press key To enter a submenu and confirm the selected setting parameter press key Moving between the different submenus and parameters...

Page 8: ...e of the case During the recharging the scale can operate or can be switched off The battery is fully recharged for approximately 8 hours The current voltage of the battery can be checked from menu 1...

Page 9: ...overloading indication a load over the maximum capacity is placed on the platform VEDICOM LTD BULGARIA 1784 Sofia 131 Tzrigradsko shose centre AD 5th floor office 526 tel fax 02 965 85 57 58 5800 Ple...

Reviews: