4.

CHARGING/RECHARGING

Lead-acid batteries require routine maintenance to ensure a full charge and long battery life. All

batteries lose energy from self-discharge over time and more rapidly when they are at higher

temperatures. Therefore, batteries need periodic charging to replace energy lost through self-

discharge. When the unit is not in use, Vector recommends that the battery is recharged at least

every 60 days. 

NOTE: 

RECHARGING BATTERY AFTER EACH USE WILL PROLONG BATTERY LIFE; 

FREQUENT HEAVY DISCHARGES BETWEEN RECHARGES WILL REDUCE BATTERY 

LIFE. OVERCHARGING WILL REDUCE BATTERY LIFE.

The battery can be recharged using an AC or DC adapter. (See FIGURES 3A and 3B)

FIGURE 3

Check the battery charge level by pressing the battery status button. The LED charge status display

will indicate the level of battery charge. When only one red LED lights, recharge the unit. 

4.1 AC 

RECHARGE 

The AC recharge adapter is a UL approved “wall” type unit that operates from any 110/120 volt,

60 Hz AC supply that has a standard North American outlet. The adapter has a barrel 

connector that plugs into the unit’s recharge port. 
Make sure the safety switch and worklight are turned OFF during AC recharge. When a 

powered AC recharge adapter is plugged into the recharge port, the battery charge level display

will automatically activate. As recharge progresses, the red LEDs will light one by one. Charge

the unit until the battery charge level display lights or flashes the green FULL LED. Continue to

recharge for one to two hours, and then disconnect the recharge adapter. AC recharge system is

an automatic taper charge and can be left connected to the main unit for long periods. (See

FIGURE 1 for AC recharge port location).

4.2 

DC TO DC RECHARGE 

Recharging the Compact Elite from an external DC power source requires the use of the DC/DC

adapter.  This adapter has a male DC connector at each end.  (See FIGURE 3B)

Unlike the AC recharge method, DC recharge does NOT automatically activate the “battery 

status” display and provide a taper charge.  Battery status can still be monitored by pressing the

battery status check switch.

CAUTION:

Make sure ON/OFF Safety Switch and Area Light are Turned OFF During Recharge

As This May Slow Recharge Function

Procedure:

1. Insert the DC adapter plug into the Compact Elite’s 12 volt accessory outlet.

2. Plug the other DC plug into an accessory outlet in a vehicle, power supply or other 12 volt DC

source.

3. Charge until the “green” battery status indicator is lit.

(DO NOT EXCEED 3 HOURS MAXIMUM)

4. After charging, disconnect the cables and store them properly.

110/120

VOLT AC

RECHARGE

ADAPTER

12 VOLT DC to DC 

ADAPTER

(A)

(B)

Summary of Contents for START-IT

Page 1: ...ATION REGARDING SAFETY OPERATION MAINTENANCE AND STORAGE OF THIS PRODUCT BEFORE USING READ AND UNDERSTAND ALL CAUTIONS WARNINGS INSTRUCTIONS AND PRODUCT LABELS PLUS YOUR VEHICLE S BATTERY MANUFACTURER...

Page 2: ...electrical cords and outlets to get wet electrical shock could result 7 Jump start procedures should only be performed in a safe dry well ventilated area 8 Always store battery clamps in built in hol...

Page 3: ...hat is not recommended or provided by the manufacturer 4 Do not use this unit to operate appliances that draw more than 12 amps 5 This system is designed to be used only on vehicles with 12 volt DC ba...

Page 4: ...SYSTEM 7 2 1 JUMP START WARNINGS 7 2 2 FIRST AID 7 2 3 JUMP START PROCEDURE 8 3 USE AS A 12 VOLT DC PORTABLE POWER SUPPLY 8 4 CHARGING RECHARGING 9 4 1 AC RECHARGE 9 4 2 DC RECHARGE 9 10 5 MAINTENANC...

Page 5: ...power source by powering DC appliances on the road at the beach or wherever your travels take you It can also be used with other Vector 12 volt DC cordless portable rechargeable appliances rated at 12...

Page 6: ...sted and listed 8 Easy to read LED battery charge status display activated by pressing the charge status button and automatically activated during AC recharge Refer to Sections 4 1 and 4 2 for use of...

Page 7: ...starting this type of vehicle read the vehicle s owner s manual to confirm that external starting assistance is advised 12 Power safety switch should be off prior to jump starting 13 Excessive engine...

Page 8: ...followed by the clamp connected to the battery positive terminal 11 Carefully press negative black jumper cable wire into storage channel starting at end away from the clamp 12 Squeeze negative black...

Page 9: ...adapter is plugged into the recharge port the battery charge level display will automatically activate As recharge progresses the red LEDs will light one by one Charge the unit until the battery char...

Page 10: ...L Contains a maintenance free sealed non spillable lead acid battery which must be disposed of properly Recycling is required contact your local authority for information Failure to comply with local...

Page 11: ...shipping charges LIMITATIONS This warranty does not cover accessories bulbs fuses and batteries defects resulting from normal wear and tear including chips scratches abrasions discoloration or fading...

Page 12: ...a proper 12 volt adapter connection B Make sure jumpstart has a full charge C If unit shuts off disconnect 12 volt outlet and let cool for 10 minutes Note When pulling more than 12 amps from the 12 vo...

Reviews: