WARNING!

Do Not DC Charge for more than 3 Hours Maximum.

Do Not Leave Unattended while DC Charging.

5.

MAINTENANCE/REPLACEMENT PARTS

For replacement parts (bulbs, batteries, charging adapters, etc.), contact Vector Technical 

Support: (954) 584-4446 or toll free (866) 584-5504. There are no user serviceable parts

inside the unit. Periodically, the cables and connectors should be inspected for damage,

corrosion, dust, and dirt. If surfaces are dirty, they can be wiped clean with a cloth moistened

with water and a drop of detergent. Contacts can be wiped clean with a dry cloth.

WARNINGS:

DO NOT OPERATE UNIT IF THERE IS ANY EVIDENCE OF DAMAGE. THE

PRODUCT MUST BE RETURNED TO VECTOR FOR TESTING AND REPAIR. 

REPLACE  ANY DAMAGED CHARGING ADAPTERS IMMEDIATELY BEFORE 

FURTHER USE.

6.

BATTERY DISPOSAL

Contains a maintenance-free, sealed, non-spillable, lead acid battery, which must 

be disposed of properly. Recycling is required - contact your local authority for 

information. Failure to comply with local, state and federal regulations can 

result in fines or imprisonment.

WARNINGS

•  Do not dispose of the battery in fire, as this may result in an explosion

•  Before disposing of the battery, protect exposed terminals with 

heavy-duty electrical tape to prevent shorting (shorting can result in injury or fire)

• Do not expose battery to fire or intense heat, as it may explode

7.

SPECIFICATIONS

Jump-Start Clamps  ............................................................300 Amps - Heavy Duty Copper
Jumper Cables  ..............................................................................#6AWG Welding Cable
Peak Amps.  ................................................................................................................600
Instant Amps  ..............................................................................................................300 
Battery High Density AGM  ....................................12 Volt, 9 Amp Hour, Sealed, Lead-Acid
Worklight Bulb  ......................................................................12 volt, 110 mA festoon type
Accessory Outlet Protection ..................................................12 Amps Self-Resetting Breaker
Height ....................................................................................................9.5 in (24.13 cm)
Width ..........................................................................................................8 in (20.3 cm)
Depth. ..........................................................................................................5 in (12.7 cm)
Weight. ....................................................................................................8.10 lbs (3.6 kg)

CONTAINS SEALED,

NON-SPILLABLE BATTERY

Summary of Contents for START-IT

Page 1: ...ATION REGARDING SAFETY OPERATION MAINTENANCE AND STORAGE OF THIS PRODUCT BEFORE USING READ AND UNDERSTAND ALL CAUTIONS WARNINGS INSTRUCTIONS AND PRODUCT LABELS PLUS YOUR VEHICLE S BATTERY MANUFACTURER...

Page 2: ...electrical cords and outlets to get wet electrical shock could result 7 Jump start procedures should only be performed in a safe dry well ventilated area 8 Always store battery clamps in built in hol...

Page 3: ...hat is not recommended or provided by the manufacturer 4 Do not use this unit to operate appliances that draw more than 12 amps 5 This system is designed to be used only on vehicles with 12 volt DC ba...

Page 4: ...SYSTEM 7 2 1 JUMP START WARNINGS 7 2 2 FIRST AID 7 2 3 JUMP START PROCEDURE 8 3 USE AS A 12 VOLT DC PORTABLE POWER SUPPLY 8 4 CHARGING RECHARGING 9 4 1 AC RECHARGE 9 4 2 DC RECHARGE 9 10 5 MAINTENANC...

Page 5: ...power source by powering DC appliances on the road at the beach or wherever your travels take you It can also be used with other Vector 12 volt DC cordless portable rechargeable appliances rated at 12...

Page 6: ...sted and listed 8 Easy to read LED battery charge status display activated by pressing the charge status button and automatically activated during AC recharge Refer to Sections 4 1 and 4 2 for use of...

Page 7: ...starting this type of vehicle read the vehicle s owner s manual to confirm that external starting assistance is advised 12 Power safety switch should be off prior to jump starting 13 Excessive engine...

Page 8: ...followed by the clamp connected to the battery positive terminal 11 Carefully press negative black jumper cable wire into storage channel starting at end away from the clamp 12 Squeeze negative black...

Page 9: ...adapter is plugged into the recharge port the battery charge level display will automatically activate As recharge progresses the red LEDs will light one by one Charge the unit until the battery char...

Page 10: ...L Contains a maintenance free sealed non spillable lead acid battery which must be disposed of properly Recycling is required contact your local authority for information Failure to comply with local...

Page 11: ...shipping charges LIMITATIONS This warranty does not cover accessories bulbs fuses and batteries defects resulting from normal wear and tear including chips scratches abrasions discoloration or fading...

Page 12: ...a proper 12 volt adapter connection B Make sure jumpstart has a full charge C If unit shuts off disconnect 12 volt outlet and let cool for 10 minutes Note When pulling more than 12 amps from the 12 vo...

Reviews: