TO REMOVE

FLAT PINS

COMPRESSOR

GAUGE

TO 12 VOLT

DC SOURCE

INVERTER/LANTERN

POWER CABLE

FIGURE 6

     FIGURE 7

4.3.1 PROCEDURE FOR CONNECTING INVERTER TO REMOTE DC SOURCE

Open the Cable Hatch and remove the Inverter Power Cable (the one with the Lantern Extension

Cord) Press the Inverter Cover Tab and remove the Cover. Ensure that the Inverter’s Power

Switch is OFF. Then press the two tabs that lock in the Inverter and release the Inverter and slide

it out of the mounting. See Figure 4.
NOTE:

 The two flat pins on the bottom of the Inverter. One pin is wider than the other pin.

Connect the DC Recharge Cable onto these flat pins. Connect the Plug of the DC Recharge

Cable to a 12 volt DC source.

CAUTION:

When operating inverter from cigarette lighter plug, do not exceed 150 watts for long

periods of time.

4.3.2 OPERATING TIME

Assuming a typical vehicle battery is the power source, a minimum operating time of 2 to 3

hours can be expected. In most instances, 5 to 10 hours of operating time is achievable.

However, Vector recommends that the operator start the vehicle every 2 to 3 hours to recharge

the battery system. This will guard against any unexpected shutdowns of the equipment and will

ensure that there is always sufficient battery capacity to start the vehicle's engine. The inverter

will sound it's alarm when DC voltage drops to 10.6 volts.
CAUTION:

 Reverse polarity connection will result in damage to the inverter. THIS WILL VOID

THE WARRANTY.

If the inverter is connected to the incorrect polarity, the fuse will blow. If the unit does not

function after replacement of the fuse, the unit must be returned to Vector for repair. Repairs for

this type of damage are not covered by warranty.

CAUTION:

 Do not use with positive ground electrical systems (the majority of modern

Automobiles, RVs and Trucks are negative ground).

4.4

POWERING AN AC LOAD

The Power Inverter is equipped with a standard AC household-type receptacle and On/Off

Switch. Plug the power cord from the equipment you wish to operate into the AC receptacle.

The green LED will light to indicate that the unit is functioning. Make sure the wattage rating of

your equipment is within 200 watts. If so, turn on your equipment. If an audible alarm sounds,

the DC supply voltage is too low. If the inverter is connected to the Main Unit, then the battery

needs to be recharged. If the inverter is connected to another DC source, then the voltage is too

low because of a discharged battery or the wiring gauge is not heavy enough.

WARNING ABOUT OUTLET STRIP USE: Remove appliance plug from outlet strip or turn off

inverter before working on the ac appliance. multiple outlet power strips with switches & circuit

breakers only interrupt power to the "hot" receptacle terminals. the "neutral" terminals remain

powered with respect to the "ground" terminals.

Summary of Contents for Power City VEC029AC

Page 1: ...ALL CAUTIONS WARNINGS INSTRUCTIONS AND PRODUCT LABELS PLUS YOUR VEHICLE S BATTERY MANUFACTURER GUIDELINES FAILURE TO DO SO COULD RESULT IN POSSIBLE INJURY OR PROPERTY DAMAGE 4140 SW 28TH WAY FT LAUDER...

Page 2: ...puterized systems may be damaged if vehicle battery is jumpstarted Before jumpstarting this type of vehicle read the vehicle s owner s manual to confirm that external starting assistance is advised Ex...

Page 3: ...verter fuse replacement 11 5 COMPRESSOR TIRE INFLATOR 11 5 1 Compressor Use 11 5 2 Warnings 11 5 3 Tire Inflation or products with a valve stem 12 5 4 Inflate other articles without valve stem 12 5 5...

Page 4: ...terminals while preparing to jumpstart a dead battery in the dark changing a tire etc Power City is also ideal to power 12 volt DC cordless portable rechargeable appliances with ratings up to 23 ampe...

Page 5: ...and power hand tools cellular phones camcorders power tool rechargeable batteries that have an appropriate recharging adapter with a 110 volt AC standard type plug Operate using 23 ampere rated 12 Vo...

Page 6: ...clamp end of cable 8 Squeeze positive red clamp handles and slide clamp from holster 9 Connect positive red clamp to vehicle s positive battery terminal 10 Connect negative black clamp to chassis or a...

Page 7: ...e inverter and it is operating properly The red LED when lit indicates that something caused the inverter to shut down The green LED will not be lit under shutdown conditions Inverter shutdown is caus...

Page 8: ...11 and 14 5 volts DC and must be able to supply the necessary current amps to operate the load The power source may be a battery or a well regulated DC power supply To obtain a rough estimate of the...

Page 9: ...sound it s alarm when DC voltage drops to 10 6 volts CAUTION Reverse polarity connection will result in damage to the inverter THIS WILL VOID THE WARRANTY If the inverter is connected to the incorrec...

Page 10: ...iece of equipment that is generating heat above room temperature Keep the inverter away that from direct sunlight if at all possible VENTILATED Keep the area surrounding the inverter clear to ensure f...

Page 11: ...ccessory socket 5 COMPRESSOR TIRE INFLATOR This built in 12 Volt DC compressor is the ultimate compressor for all Vehicles Trailer Tires and recreational inflatables Three different sized nozzles are...

Page 12: ...very rapidly 5 Insert adaptor e g needle into item to be inflated and inflate to desired pressure 6 Turn ON compressor switch inflate to desired pressure or fullness refer to paragraph 5 5 7 Remove ad...

Page 13: ...Main Unit using the Inverter Power Cable with attached Lantern Extension Cord This allows great flexibility in positioning the Lantern during tire infla tion and during under the hood inspections See...

Page 14: ...BATTERY Lead acid batteries require maintenance to maintain a full charge and to ensure good battery life All lead acid batteries suffer from self discharge over time and more rapidly when they are a...

Page 15: ...ed in their own Cable Storage Hatch in the Main Unit Recharging the Main Unit s internal battery from an external DC power source requires the use of the DC Recharge Cable and the Inverter Power Cable...

Page 16: ...harging adapters cables etc contact Vector Technical Support 954 584 4446 or call toll free 866 584 5504 Except for a fuse in the inverter and a lamp in the Lantern there are no user serviceable parts...

Page 17: ...ower Inverter Continuous 200 Watt 60 Hz 110 120 VAC Power Inverter Peak 300 Watt 60 Hz 110 120 VAC Inverter Waveform Modified Sine Wave Inverter DC Input Range 10 0 to 14 6 VDC Inverter Audible Alarm...

Page 18: ...cratches abrasions repairs by unauthorized persons or failure to follow recommended care and use instructions Damage caused by misuse abuse neglect alterations repairs by unauthorized persons or failu...

Page 19: ...instructions Damage caused by misuse abuse neglect alterations repairs by unauthorized persons or failure to follow recommended care and use instructions Bulbs and batteries Please activate my Extende...

Page 20: ...20 2000 VECTOR MANUFACTURING Ltd FT LAUDERDALE FL 33312 MADE IN CHINA...

Reviews: