background image

14

6.3

LAMP REPLACEMENT

The only lamp is in the Lantern Assembly. For any maintenance of the lamp, you will need a

small Phillips screwdriver and a soft clean cloth. Replacement bulbs are available from Vector

Technical Support Department; call (954) 584-4446 for replacements. Warning Fluorescent

bulbs are fragile, be careful while handling.

NOTE

: DO NOT use any metal tools to remove or replace bulb. See Figure 10.

FIGURE 11

1. Make sure the Lantern is turned off.

2. Remove the Lantern Assembly from the main unit.

3. Remove the Phillips type screw (turn counter-clockwise).

4. Lift the lens upward and off and set it aside.

5. Using a clean cloth, rotate the top of the bulb away from the reflector.

6. Pull the burned out bulb upwards and towards the front of the Lantern Assembly.

This will remove it.

7. Replace with a new fluorescent 9 watt bulb.

8. Snap the lens into place (bottom tab first) and replace the two screws.

9. Carefully turn the screw clockwise to tighten. DO NOT OVER TIGHTEN screw.

10. Dispose of burned out bulb in a responsible manner. Follow local ordinances for disposal.

7.

RECHARGING POWER CITY’S BATTERY

Lead-acid batteries require maintenance to maintain a full charge and to ensure good battery

life. All lead-acid batteries suffer from self-discharge over time and more rapidly when they are

at higher temperatures. Therefore, these types of batteries need periodic charging to replace

energy lost through self-discharge. When Power City is not in use Vector recommends that the

batteries be recharged at least every 60 days.
All batteries must be recharged as soon as possible after each use. If a battery is allowed to

remain in a discharged state, battery life will be reduced.
NOTE:

 Recharging battery after each use will prolong battery life; frequent heavy discharges

between recharges will reduce battery life. Overcharging will reduce battery life.

The battery can be recharged using several different methods. The time required to fully

recharge these batteries depends on the charge status of the battery after the use of DC

appliances, Inverter and Compressor.
NOTE:

 Pressing the battery status push-button turns on the battery status display on the

main unit

Check the battery charge level by pressing the Charge Status Button. The LED Charge Status

display will indicate the level of charge of the battery.

LANTERN

LENS

LENS

RETAINING

SCREW

FLUORESCENT

LAMP

SPRING CLIP

BOTTOM

LENS TAB

Summary of Contents for Power City VEC029AC

Page 1: ...ALL CAUTIONS WARNINGS INSTRUCTIONS AND PRODUCT LABELS PLUS YOUR VEHICLE S BATTERY MANUFACTURER GUIDELINES FAILURE TO DO SO COULD RESULT IN POSSIBLE INJURY OR PROPERTY DAMAGE 4140 SW 28TH WAY FT LAUDER...

Page 2: ...puterized systems may be damaged if vehicle battery is jumpstarted Before jumpstarting this type of vehicle read the vehicle s owner s manual to confirm that external starting assistance is advised Ex...

Page 3: ...verter fuse replacement 11 5 COMPRESSOR TIRE INFLATOR 11 5 1 Compressor Use 11 5 2 Warnings 11 5 3 Tire Inflation or products with a valve stem 12 5 4 Inflate other articles without valve stem 12 5 5...

Page 4: ...terminals while preparing to jumpstart a dead battery in the dark changing a tire etc Power City is also ideal to power 12 volt DC cordless portable rechargeable appliances with ratings up to 23 ampe...

Page 5: ...and power hand tools cellular phones camcorders power tool rechargeable batteries that have an appropriate recharging adapter with a 110 volt AC standard type plug Operate using 23 ampere rated 12 Vo...

Page 6: ...clamp end of cable 8 Squeeze positive red clamp handles and slide clamp from holster 9 Connect positive red clamp to vehicle s positive battery terminal 10 Connect negative black clamp to chassis or a...

Page 7: ...e inverter and it is operating properly The red LED when lit indicates that something caused the inverter to shut down The green LED will not be lit under shutdown conditions Inverter shutdown is caus...

Page 8: ...11 and 14 5 volts DC and must be able to supply the necessary current amps to operate the load The power source may be a battery or a well regulated DC power supply To obtain a rough estimate of the...

Page 9: ...sound it s alarm when DC voltage drops to 10 6 volts CAUTION Reverse polarity connection will result in damage to the inverter THIS WILL VOID THE WARRANTY If the inverter is connected to the incorrec...

Page 10: ...iece of equipment that is generating heat above room temperature Keep the inverter away that from direct sunlight if at all possible VENTILATED Keep the area surrounding the inverter clear to ensure f...

Page 11: ...ccessory socket 5 COMPRESSOR TIRE INFLATOR This built in 12 Volt DC compressor is the ultimate compressor for all Vehicles Trailer Tires and recreational inflatables Three different sized nozzles are...

Page 12: ...very rapidly 5 Insert adaptor e g needle into item to be inflated and inflate to desired pressure 6 Turn ON compressor switch inflate to desired pressure or fullness refer to paragraph 5 5 7 Remove ad...

Page 13: ...Main Unit using the Inverter Power Cable with attached Lantern Extension Cord This allows great flexibility in positioning the Lantern during tire infla tion and during under the hood inspections See...

Page 14: ...BATTERY Lead acid batteries require maintenance to maintain a full charge and to ensure good battery life All lead acid batteries suffer from self discharge over time and more rapidly when they are a...

Page 15: ...ed in their own Cable Storage Hatch in the Main Unit Recharging the Main Unit s internal battery from an external DC power source requires the use of the DC Recharge Cable and the Inverter Power Cable...

Page 16: ...harging adapters cables etc contact Vector Technical Support 954 584 4446 or call toll free 866 584 5504 Except for a fuse in the inverter and a lamp in the Lantern there are no user serviceable parts...

Page 17: ...ower Inverter Continuous 200 Watt 60 Hz 110 120 VAC Power Inverter Peak 300 Watt 60 Hz 110 120 VAC Inverter Waveform Modified Sine Wave Inverter DC Input Range 10 0 to 14 6 VDC Inverter Audible Alarm...

Page 18: ...cratches abrasions repairs by unauthorized persons or failure to follow recommended care and use instructions Damage caused by misuse abuse neglect alterations repairs by unauthorized persons or failu...

Page 19: ...instructions Damage caused by misuse abuse neglect alterations repairs by unauthorized persons or failure to follow recommended care and use instructions Bulbs and batteries Please activate my Extende...

Page 20: ...20 2000 VECTOR MANUFACTURING Ltd FT LAUDERDALE FL 33312 MADE IN CHINA...

Reviews: