The guarantee is subject to the following 
provisions:

  The guarantee does not cover normal wear, 
accidental damage, misuse, damage or used for a 
purpose for which is not designed; altered in any 
way; or subjected to any but the specified voltage 
if applicable.

   The product must be operated only by trained 
and skilled personnel and it must be correctly 
handled and operated in accordance with the 
instructions contained in this manual. The 
functional safety of the unit (e.g. by trial fogging 
with water) must be checked before putting the 
unit in operation. Any loose or leaking valves or 
lines should be repaired and fixed. If functional 
safety is not ensured, do not put the unit into 
operation.

   The guarantee will be rendered invalided if the 
product is re-sold, fitted with non-original spare 
parts or damaged by inexpert repair.

    Chemical solutions must be officially approved 
for the intended application and the material 
safety data sheet of the chemical solution should 
be revised prior to operation. Oxygen and 

PRODUCT

GUARANTEE

chlorine releasing chemicals (e.g. peroxides) and 
other acids should only be used with approved 
acid resistant equipment models. If not approved 
for acid resistance a Ph-value should be limited 
from 4,5-8,5. After use, fog with some clean water 
for about 3 minutes to remove any chemicals still 
left in the system. Ensure all the water is used up 
and the machine is dried prior to storage. 
Damage caused by corrosion due to humidity by 
wrongful storage will invalidate this guarantee

   Any formation of aerosols or fogs from flamma-
ble substances or acids releasing oxygen and a 
mixture with air and/or dust always involves the 
risk of fire or explosion if there is a source of 
ignition. Observe the explosion limit of a 
pesticide and avoid over dosage accordingly. 
Only use non-inflammable liquids (without a flash 
point) for treatments in rooms where a dust 
explosion hazard exists. Unit is not explosion 
proof.

  Operators owe a duty of care to prevent 
unreasonable risk of harm or injury. Operators 
should not fog towards hot surfaces or electric 
cables nor fog in rooms with a temperature 
exceeding 35°C. Only treat closed rooms. 
Position the unit in a safe and upright position 
with the hand piece hooked or carry it with the 
strap over your shoulder. In case of stationary 
use, do not leave the unit unattended. Secure 
treated rooms against unauthorized access (i. e. 
provide warnings outside). Always keep treated 
rooms closed and eliminate leakages. Ventilate 
treated rooms sufficiently before re-using them. If 
the machine stops fogging unintentionally, close 
the gas valve immediately and turn the chemical 
supply valve off (dripping of chemical may occur)

  Specifications are subject to change without 
notice. The manufacturer disclaims any liability 
for the incidental or consequential damages. The 
guarantee is in addition to, and does not diminish 
your statutory or legal rights. In the event of a 
problem with the product within the guarantee 
period call the 

Customer Helpline: (UK)+44 

(0)203 808 5797 I (KOREA) +82 (0)70 4694 
2489 I (US) +1 201 482 9835

G

UA

RANTE

E

G

UA

R A NTE

E

This product is guaranteed for twelve 
months from the date of original 
purchase. Any defect that arises due to 
faulty materials or workmanship will 
either be replaced or repaired during this 
period by the seller or authorized 
distributor from whom you purchased 
the unit. Transportation charges or 
duties shall be borne by Purchaser.

Summary of Contents for DC20P

Page 1: ...2019 Vectorfog is a trademark of Vectornate USA All right reserved DC20 ULV FOGGER User Manual www vectorfog com...

Page 2: ...cold fog generated from the machine The micro droplets produced by this machine can float in the air for a long time and are quickly absorbed by the lungs Depending on the chemical being used this co...

Page 3: ...ry Can be operated anywhere without power cord after the battery has been charged Solution Compatibility Compatible with different types of solutions such as water oil air freshener and others Quiet C...

Page 4: ...andle turns red CHARGING 1 2 3 4 4 1 4 2 Connect the charger to the power cable Connect the charger to the charging port on the handle Plug in the power cord to the main power supply Battery takes 3 h...

Page 5: ...inlet Close the cap of the tank securely to prevent chemical leakage FILLING THE TANK The tank capacity is only 2 Liters Do not fill up the tank with solution while recharging the battery Do not fill...

Page 6: ...e machine by sliding the switch to the ON position Turn off the machine by sliding the swtich to the OFF position Adjust the droplet size by turning the nozzle on the front of the machine Clockwise re...

Page 7: ...ny existing liquid remaining in the fogger s internal tubes STEP A Fill the fogger with some clean water and operate again for one minute Remove any excess water from the tank STEP B CLEANUP OF EMULSI...

Page 8: ...PRODUCT www vectorfog com 07 1 2 3 Air Cap Cap Nozzle Nozzle Assy Body Assy Motor Assy Battery Assy 4 5 6 1 8 17 14 19 2 11 10 12 3 6 7 5 15 18 16 4 9 13...

Page 9: ...orfog com 08 PRODUCT 7 8 9 Battery Invertor Switch Assy 10 11 12 PCB Switch PCB Check Valve 13 14 15 Elbow Hose Tank Assy 16 17 18 Tank Cap Air Nipple Water Nipple 19 20 21 Packing Battery Charger Pow...

Page 10: ...y charged Input Voltage Output Voltage Current I Charging Time 2L 0 5 gal 3 2 kg 7 05 lb 2 0 13 1 500 sq ft 140 m 15 20 L h 4 5 3 gal h 100 L min 26 gal min 5 50 Microns 80 Degrees Cordless Ningbo Dec...

Page 11: ...mixture with air and or dust always involves the risk of fire or explosion if there is a source of ignition Observe the explosion limit of a pesticide and avoid over dosage accordingly Only use non i...

Page 12: ...UK 44 0 20 3808 5797 KOREA 82 0 70 4694 2489 US 1 201 482 9835 UK OFFICE KOREA OFFICE US OFFICE Info vectorfog com www vectorfog com...