www.vectorfog.com
06
CLEANING
Clean the fogger after every use
to extend the life of the fogger.
CLEANUP OF WATER BASED LIQUIDS
When fogging is complete, pour any liquid left in the tank to a suitable container using
a funnel. Operate the fogger for one minute with the nozzle opened to the largest
droplet size setting (anti-clockwise). This will get rid of any existing liquid remaining in
the fogger's internal tubes.
STEP A
Fill the fogger with some clean water and operate again for one minute. Remove any
excess water from the tank.
STEP B
CLEANUP OF EMULSIONS
After fogging, begin with "STEP A”. Fill the tank with appropriate solvent for the chemical
that was used. Operate the machine for 1 minute to flush any residual chemical left
inside. Repeat "STEP B". Allow the machine to dry before storing in a safe place.
Unplug fogger's power cord from the power source
before attempting any cleaning or maintenance.
WARNING