4.3 check and clean the tip
1 Set the temperature to 250
℃
.
2 When the temperature stabilizes, clean the tip with the cleaning sponge and check the condition
of the tip.
3 If there is black oxide on the solder-plated portion of the tip, coat new solder (containing flux)
and then wipe the tip on the cleaning sponge. Repeat until the oxide is completely removed and
then coat with the new solder.
3 off time setting
If the station isn‟t resumed
during the sleeping time, the power supply will
be shut off automatically,
and the station will stop working. Turn on the
power switch to resume working.
1)
The process of setting “off time” is after the process of setting “sleep time”. At the “off time ”
status, the display shows
and then press
“△”
or
“▽”
key to change the off time.
2)
The range of sleeping time is from 0 minute to 250 minutes.
3)
After finishing the off time setting, press
“*”
key to the process of off time setting.
Note: * the off time should be longer than the sleep time, otherwise, the soldering station will
be turned off immediately after it comes into sleep state.
4 sleeping temperature setting
1) In the process of “sleeping temperature” setting, the display shows “sleep” and “set temp” , and
then press
“△”
or
“▽”
key to change the sleeping temperature.
2) The range of sleeping temperature is from 50
℃
to 250
℃
3) In the sleeping state, if the sleeping temperature is less than the setting temperature of the
soldering station, the temperature will fall down to the sleeping temperature. Otherwise, down
to the soldering station‟s setting temperature.
Such as:
If the setting sleeping temperature is 200
℃
and the setting work temperature is 280
℃
,
in sleeping state, the iron‟s temperature will fall down to 200
℃
.
If the setting sleeping temperature is 200
℃
and the setting work temperature is 150
℃
,
in sleeping state, the iron‟s temperature in sleeping will fall down to 150
℃
.
5 up temp setting
1) In the up temp setting state, the display shows “Up Temp”(refer to the picture) and press “
△
” or
“
▽
” key to change the temperature. Once difference in temperature between the real
temperature (Real Temp) and the setting temperature (set temp) is bigger than the up temp, the
soldering station will alarm when in the
alarming mode.
0
℃
to 99
℃
.
2) The range of the “up temp” setting is from
Up Temp setting
6 down temp setting
1) In the down temp setting, the display shows “Down Temp”(refer to the picture) and press “
△
”
or “
▽
” key to change the temperature. Once difference in temperature between the real
temperature (Real Temp) and the setting temperature (set temp) is bigger than the Down Temp,
the soldering station will alarm when in the alarming mode.
2) The range of the “Down Temp” is from 0
℃
to 99
℃
.
Down Temp setting
3.4 Calibrating the temperature
1 The soldering iron should be recalibrated every time after replacing the iron, the heating element
or the tip.
2 This device adopts digital calibration mode and input the revision value by pressing key.
Sleeping temperature setting
Page9
Page12