background image

83

©Vecow RCX-1500 PEG User Manual  

Appendix A

A

APPENDIX A : Isolated DIO Guide

A.1  Function Description

The RCX-1520 (RCX-1000 series) offers two 16-bit Isolated DIO 20-pin terminal 

block connector, a watchdog timer.

Isolated DIO pins are fix by Hardware design that cannot change in/out direction 

in runtime process.

DIO definition is shown below :

Pin No.

Isolated DIO

Non-Isolated 

DIO

Definition

Pin No.

Isolated DIO

Definition

Non-Isolated 

DIO

Definition

1

DI 0

DIO 0

11

DO 0

DIO 8

2

DI 1

DIO 1

12

DO 1

DIO 9

3

DI 2

DIO 2

13

DO 2

DIO 10

4

DI 3

DIO 3

14

DO 3

DIO 11

5

DI 4

DIO 4

15

DO 4

DIO 12

6

DI 5

DIO 5

16

DO 5

DIO 13

7

DI 6

DIO 6

17

DO 6

DIO 14

8

DI 7

DIO 7

18

DO 7

DIO 15

9

DI COM

NC

19

DIO_GND

DIO_GND

10

DIO_GND

DIO_GND

20

External VDC

NC

Summary of Contents for RCX-1500 PEG

Page 1: ...USER Manual USER Manual 2 2 0 Edition 20191213 Intel Xeon Core i7 i5 i3DualGPUAIComputingSystem Workstation grade NVIDIA Tesla Quadro GeForce Graphics RCX 1500 PEG...

Page 2: ...Page Description Remark 0 10 2019 06 14 All Preliminary Release 1 00 2019 07 01 All Official Release 2 00 2019 07 24 iv v 1 2 3 5 7 Update 2 10 2019 10 05 Cover iv 1 2 3 5 7 9 44 45 49 98 99 Update 2...

Page 3: ...dio frequency energy and if it is not installed and used in accordance with the instruction manual it may cause harmful interference to radio communications Operation of this equipment in a residentia...

Page 4: ...s SSD Tray 3 COM 6 USB 3 1 2 SIM 32 Isolated DIO RCX 1520 PEG RCX 1520 PEG Dual NVIDIA Graphics Card 2 GigE LAN 3 COM 6 USB 3 1 2 SIM 32 Isolated DIO Order Information CPU List Series CPU Cores GHz TD...

Page 5: ...pitch Wide Temperature 30 C to 70 C PWS 700W 12V 700W 12V 90V AC to 264V AC Power Supply PWS 1500W 12V 1500W 12V 90V AC to 264V AC Power Supply FAN Sink Fan Sink for RCX 1500 Series TMK2 20P 100 Term...

Page 6: ...imensions of RCX 1500R PEG 8 1 5 2 Dimensions of RCX 1500 PEG 8 CHAPTER 2 GETTING TO KNOW YOUR RCX 1500 PEG 9 2 1 Packing List 9 2 2 Front Panel I O Functions 10 2 3 Main Board Expansion Connectors 22...

Page 7: ...Hold down Kit 60 CHAPTER 4 BIOS AND DRIVER 61 4 1 Entering BIOS Setup 61 4 2 Main 62 4 3 Advanced 62 4 4 Chipset 73 4 5 Security 79 4 6 Boot 81 4 7 Save Exit 82 APPENDIX A Isolated DIO Guide 83 APPEND...

Page 8: ...ate 4 front access 2 5 SSD HDD trays with RAID 0 1 5 10 data protection multiple WiFi 4G 3G LTE GPRS UMTS for seamless wireless data transfer 3 COM RS 232 422 485 2 M 2 expansions 32 Isolated DIO 6V t...

Page 9: ...ort display interfaces support max 11 independent displays up to 8K resolution 6 ports external USB 3 1 Gen 2 support up to 10Gbps data transfer 2 independent GigE LAN iAMT 12 0 supported 2 external S...

Page 10: ...ternal SIM Card Socket Expansion Mini PCIe 2 Full size for PCIe USB External SIM Card mSATA M 2 1 M 2 Key E Socket PCIe 2 PCIe x16 Slot with x8 Signal 1 PCIe x16 Slot with x4 signal Optional 1 PCIe x1...

Page 11: ...neon SLB9665 supports TPM 2 0 LPC interface Watchdog Timer Reset 1 to 255 sec min per step Smart Management Wake on LAN PXE supported HW Monitor Monitoring temperature voltages Auto throttling control...

Page 12: ...PCIe USB External SIM Card mSATA M 2 1 M 2 Key E Socket PCIe 2 PCIe x16 Slot with x8 Signal 1 PCIe x16 Slot with x4 signal Optional 1 PCIe x16 Slot with x1 signal Optional Graphics Graphics Processor...

Page 13: ...atchdog Timer Reset 1 to 255 sec min per step Smart Management Wake on LAN PXE supported HW Monitor Monitoring temperature voltages Auto throttling control when CPU overheats Software Support OS Windo...

Page 14: ...Intel Xeon E 2176G 6 4 6 80 E 2278GE 8 4 7 80 Yes E 2278GEL 8 3 9 35 E 2124G 4 4 5 71 E 2226GE 6 4 6 80 Intel Core i7 8700 6 4 6 65 i7 9700E 8 4 4 65 N A i7 8700T 6 4 35 i7 9700TE 3 8 35 i5 8500 6 4...

Page 15: ...5 1 Dimensions of RCX 1500R PEG 210 0 8 27 160 0 6 30 350 13 78 382 15 04 402 15 83 R2 5 0 10 R4 5 0 18 198 2 7 80 205 5 8 09 Unit mm inch 1 5 2 Dimensions of RCX 1500 PEG 210 0 8 27 160 0 6 30 350 1...

Page 16: ...F Head 6 32x6 screw for wall mounting bracket PH Head M2 5x6 screw for Mini PCIe Slot PH Head M3x6 screw for M 2 Slot Terminal block plug pitch 2 54mm 2x10pin Terminal block 3 pin 7 62mm Terminal bloc...

Page 17: ...ed on the front panel 2 2 1 Reset Tact Switch Isolated DIO 1 DVI I DP Digital Display LAN 1 10 COM 4 COM 3 COM 1 Isolated DIO 2 DC IN V V SIM 2 SIM 1 RST LAN 2 10 10 On Off IGN V V PEG Power The item...

Page 18: ...er button which will light the blue LED To power off RCX 1500 PEG you can either command shutdown by OS operation or simply press the power button If system error appears press and hold the power butt...

Page 19: ...DVI I DP Digital Display LAN 1 10 COM 4 COM 3 COM 1 Isolated DIO 2 DC IN V V SIM 2 SIM 1 RST LAN 2 10 10 On Off IGN V V PEG Power 2 2 4 DVI I Connector The DVI I connector on the front panel supports...

Page 20: ...USB 3 1 There are 6 USB 3 1 connections available supporting up to 10GB per second data rate in the front side of Vecow RCX 1500 PEG series It also compliant with the requirements of Super Speed SS hi...

Page 21: ...n normal status iAMT 12 0 function is enabled Using suitable RJ 45 cable you can connect the RCX 1500 PEG system to a computer or to any other devices with Ethernet connection for example a hub or a s...

Page 22: ...10Mbps 100Mbps 1000Mbps Left Green Orange Off Solid Green Solid Orange Right Yellow Blinking Yellow Blinking Yellow Blinking Yellow 1 8 2 2 9 Audio Connector There are two audio connectors mic in and...

Page 23: ...o 16TB available 2 2 10 Front access SSD HDD Tray DVI I DP Digital Display LAN 1 10 COM 1 DC IN V V SIM 1 RST LAN 2 10 10 On Off IGN V V PEG Power RCX 1500 PEG supports 6V to 36V DC power input Pin No...

Page 24: ...V V PEG Power There is a 16 bit 8 bit DI 8 bit DO connectors in the rear side DI DIO support NPN sink and PNP Source mode Each DI channel is equipped with a photocouper for isolated protection Each D...

Page 25: ...IO_GPO74 16 OUTPUT 5 SIO_GPO75 17 OUTPUT 6 SIO_GPO76 18 OUTPUT 7 SIO_GPO77 19 GND_ISO_DIO1 20 External 6 40VDC NPN External 6 48VDC PNP DIO2 Connectors pin out DIO Pin No Definition Function DIO 2 1 I...

Page 26: ...ISOLATION LOGIC Driver OCP OTP VCCI VEXT GNDI GNDO INX OUTX ENX DIO_VDC 20 OUT 11 GNDO 10 19 Internal Circuit External Device DO Signal circuit in SINK mode NPN 300mA LOAD VDD 6 40V VDC P N R I DO re...

Page 27: ...COM 3 COM 4 RS 232 RS 422 5 wire RS 422 9 wire RS 485 RS 485 w z auto flow control The pin assignments are listed in the table as follows Serial Port Pin No RS 232 RS 422 5 wire RS 422 9 wire RS 485 3...

Page 28: ...TING TO KNOW YOUR RCX 1500 PEG PEG Power V V 12V Only GND 2 2 15 PEG External Power Max 700W Isolated DIO 1 DVI I DP Digital Display LAN 1 10 COM 4 COM 3 COM 1 Isolated DIO 2 DC IN V V SIM 2 SIM 1 RST...

Page 29: ...sion Connectors 2 3 1 Front View of RCX 1500 PEG Main Board With Connector Location SODIMM 2 SODIMM 1 SODIMM 4 SODIMM 3 CN6 CN8 CN10 JCOM2 JCOM1 J2 SATA4 SATA3 SATA1 SATA2 HDD_PWR2 HDD_PWR1 CN9 M2_KEY...

Page 30: ...23 Vecow RCX 1500 PEG User Manual GETTING TO KNOW YOUR RCX 1500 PEG 2 3 2 Rear View of RCX 1500 PEG Main Board With Connector Location CN17 PCH CPU...

Page 31: ...ition Pin No Definition 1 GND 3 Fan speed sensor 2 12V up to 2A 4 Fan PWM 2 3 4 JBAT1 Battery The RCX 1500 PEG s real time clock is powered by a lithium battery It is equipped with Panasonic BR2032 19...

Page 32: ...A9 V3 3S B9 Reserved A10 V3 3S B10 V3 3A A11 PLTRST_PCIE B11 WAKE A12 GND B12 Reserved A13 CLKOUT_100M_X4_P0 B13 GND A14 CLKOUT_100M_X4_N0 B14 PCIE_TXP21 A15 GND B15 PCIE_TXN21 A16 PCIE_RXP21 B16 GND...

Page 33: ...A3 V12S B3 V12S A4 GND B4 GND A5 CLKOUT_100M_X16_P2 B5 SM_SLOT_CLK A6 CLKOUT_100M_X16_N2 B6 SM_SLOT_DAT A7 USB_P8_DP B7 GND A8 USB_P8_DN B8 V3 3S A9 V3 3S B9 GND A10 V3 3S B10 V3 3A A11 PLTRST_PCIE B...

Page 34: ..._3 A29 PEG_RXP_3 B29 GND A30 PEG_RXN_3 B30 PCIE_RXP7 A31 GND B31 PCIE_RXN7 A32 CLKOUT_100M_X16_P1 B32 GND A33 CLKOUT_100M_X16_N1 B33 PEG_TXP_4 A34 GND B34 PEG_TXN_4 A35 PEG_RXP_4 B35 GND A36 PEG_RXN_4...

Page 35: ...PEG_RXN_10 B61 GND A62 GND B62 PEG_TXP_11 A63 GND B63 PEG_TXN_11 A64 PEG_RXP_11 B64 GND A65 PEG_RXN_11 B65 GND A66 GND B66 PEG_TXP_12 A67 GND B67 PEG_TXN_12 A68 PEG_RXP_12 B68 GND A69 PEG_RXN_12 B69...

Page 36: ...TA2 There are four onboard high performance Serial ATA III s SATA III on RCX 1500 PEG It supports higher storage capacity with less cabling effort and smaller required space The pin assignments of SAT...

Page 37: ...6 LPC_AD3 7 LPC_FRAME 8 CLK_LPC_80 9 BUF_PLTRST_N_B 10 GND 2 3 9 HDD_PWR1 HDD_PWR2 SATA Power Connector HDD_PWR1 The RCX 1500 PEG is also equipped with two SATA power connectors It supports 5V Up to 3...

Page 38: ...GND 2 3 11 JUSB1 Internal Dual Port USB 2 0 JUSB1 The RCX 1500 PEG main board provides up to two expansion USB ports using plug and play for Dongle Key or LCD touch panel The USB interface supports 4...

Page 39: ...is plugged into the socket until recently that SATA I O issued an ECN change ECN 045 to redefine pin 43 on mSATA connector as no connect instead of return current path or GND When an mSATA drive is in...

Page 40: ...USB_D 35 GND 36 USB_D 33 PETp0 34 GND 31 PETn0 32 SMB_DATA 29 GND 30 SMB_CLK 27 GND 28 1 5V 25 PERp0 26 GND 23 PERn0 24 3 3Vaux 21 GND 22 PERST 19 Reserved 20 reserved 17 Reserved 18 GND Mechanical Ke...

Page 41: ...to 36V DC power input CN6 support 12V output The pin assignments of CN6 are listed in the following table Pin No Definition Pin No Definition 1 GND 2 GND 3 GND 4 GND 5 V12_ATX 6 V12_ATX 7 V12_ATX 8 V1...

Page 42: ...n header can be used as a backup for following functions hard drive LED indicator reset button power LED indicator and power on off button The pin assignments of J2 are listed in the following table G...

Page 43: ...G TO KNOW YOUR RCX 1500 PEG SODIMM_2 SODIMM_2 SODIMM_4 SODIMM_2 SODIMM_1 SODIMM_4 SODIMM_2 SODIMM_1 SODIMM_4 SODIMM_3 SODIMM Quantity Location 1 SODIMM_2 2 SODIMM_2 SODIMM_4 3 SODIMM_2 SODIMM_4 SODIMM...

Page 44: ...75 GND 72 3 3V 73 RESERVED REFCLKn1 70 NC 71 RESERVED REFCLKp1 68 NC 69 GND 66 NC 67 RESERVED PETn1 64 NC 65 RESERVED PETp1 62 ALERT O 0 3 3V 63 GND 60 12C_CLK I 0 3 3V 61 RESERVED PERn1 58 12C_DATA I...

Page 45: ...6 LED1 O od 7 GND 4 3 3V 5 USB_D 2 3 3V 3 USB_D 1 GND 2 3 17 M2_KEYM_CN1 PCIe x4 SATA Support M 2 key M connector is suitable for applications that use Host I Fs supported by either PCIe or SATA or So...

Page 46: ...3V or N C 53 REFCLKn 50 PERST I O O 0 3 3V or N C 51 GND 48 N C 49 PETp0 SATA A 46 N C 47 PETn0 SATA A 44 N C 45 GND 42 N C 43 PERp0 SATA B 40 N C 41 PERp0 SATA B 38 DEVSLP O 39 GND 36 N C 37 PETp1 34...

Page 47: ...K_1 6 UIM_CLK_2 7 UIM_RESET_1 8 UIM_RESET_2 9 UIM_VPP_1 10 UIM_VPP_2 11 SIO_GPI80 12 DIO2_GPI0 13 SIO_GPI81 14 DIO2_GPI1 15 SIO_GPI82 16 DIO2_GPI2 17 SIO_GPI83 18 DIO2_GPI3 19 SIO_GPI84 20 DIO2_GPI4 2...

Page 48: ...RT4_CTS 59 UART3_RI 60 UART4_RI 61 UART3_MODE0 62 UART4_MODE0 63 UART3_MODE1 64 UART4_MODE1 65 UART3_MODE2 66 UART4_MODE2 67 SP338E_TERM_COM3 68 SP338E_TERM_COM4 69 V3 3S 70 V3 3S 71 V3 3S 72 V3 3S 73...

Page 49: ...close an electric circuit It consists of two metal pins and a small metal clip often protected by a plastic cover that slides over the pins to connect them To close a jumper you connect the pins with...

Page 50: ...No Definition COM1_RI 1 2 5V 1A max 3 4 12V 0 5A max 5 6 RI Default Pin Header Pin No Definition COM2_RI 1 2 5V 1A max 3 4 12V 0 5A max 5 6 RI Default 2 4 3 JP1 CPU PCIe x 16 CN9 Configuration JCFG1...

Page 51: ...efault 2 3 Clear CMOS 2 4 5 JUSB_PWR1 Pin Header USB Wake Up JUSB_PWR1 Pin No Definition 1 2 USB 3 0 and USB 2 0 Wake Up Enable Default 2 3 USB 3 0 and USB 2 0 Wake Up Disable Isolated DIO 1 DVI I DP...

Page 52: ...45 Vecow RCX 1500 PEG User Manual GETTING TO KNOW YOUR RCX 1500 PEG 2 4 6 FAN2 Header FAN2 Pin No Definition 1 2 SYS_FAN2 PCH PWM Control Default 2 3 SYS_FAN2 Full Speed...

Page 53: ...EG 2 5 Ignition Control 2 5 1 SW1 Ignition Control The RCX 1500 PEG series provide ignition power control feature for in vehicle applications The built in MCU monitors the ignition signal and turns on...

Page 54: ...y Power off delay Switch Position 0 ATX AT mode Default 1 No delay No delay 2 No delay 5 seconds 3 No delay 10 seconds 4 No delay 20 seconds 5 5 seconds 30 seconds 6 5 seconds 60 seconds 7 5 seconds 9...

Page 55: ...u can refer to the picture blow to simulate ignition signal input controlled by a latching switch Note 1 DC power source and IGN share the same ground 2 RCX 1500 PEG supports 6V to 36V wide range DC p...

Page 56: ...49 Vecow RCX 1500 PEG User Manual SYSTEM SETUP SYSTEM SETUP 3 1 How to open your RCX 1500 PEG Remove F Head 6 32 screws marked in red on the top cover 11 places 3...

Page 57: ...50 Vecow RCX 1500 PEG User Manual SYSTEM SETUP 3 2 Installing CPU Step 1 Remove PH M3x6L screws 10 places...

Page 58: ...SO DIMM slot Step 2 Make sure the RAM module is locked by the memory slots red Step 3 Push the slot key Step 4 Check CPU and CPU slot lock pin Step 5 Close the slot key and make sure the key is in the...

Page 59: ...SYSTEM SETUP 3 4 Installing Mini PCIe Card 3 5 Installing M 2 Key E Key M Step 1 Install M 2 card into the Mini PCIe slot Step 1 Install Mini PCIe card into the Mini PCIe slot Step 2 Fasten one M2 5 s...

Page 60: ...53 Vecow RCX 1500 PEG User Manual SYSTEM SETUP 3 6 Installing Antenna Cable Step 1 Remove one halt shear hole from the rear panel pick up the location you want...

Page 61: ...ETUP Step 2 Check antenna parts cable and washers Step 3 Fasten washer 1 washer 2 and on Antenna cable connector 2 1 2 1 3 7 Installing Sim Card Step 1 Remove SIM cover Remove 6 32 x 5Lscrews Step 2 I...

Page 62: ...EG User Manual SYSTEM SETUP 3 8 Installing PCI PCIe Card Supports the full length 312mm without card bracket 124 5mm height and 2 5 Slot card widthof PCI PCIe expansion card Step 1 Remove the M3x5L sc...

Page 63: ...56 Vecow RCX 1500 PEG User Manual SYSTEM SETUP Notice please press the clip before removing the card Step 3 Tighten one M3x5L screws Step 2 Install the PCI PCIe Card and lock it in place...

Page 64: ...g SSD HHD The 2 5 hard drive works with both 9 5mm and 7mm drives 3 9 1 External SSD HDD for RCX 1500FR PEG Step 1 Unlock SSD HDD Tray Step 2 Install 2 5 SSD HDD into the tray Step 3 Close the SSD HDD...

Page 65: ...500 PEG User Manual SYSTEM SETUP 3 9 2 Internal SSD HDD for RCX 1500 PEG Step 1 Remove 6 32 x 5L screws Step 2 Unlock the HDD tray and install 2 5 SSD HDD into the tray Step 3 Tighten four F Head M3x4...

Page 66: ...59 Vecow RCX 1500 PEG User Manual SYSTEM SETUP 3 10 Mounting Your RCX 1500 PEG Step 1 Install wall mount to RCX 1500 bottom Step 2 Install four F head 6 32x6L screws...

Page 67: ...nd R2 however the position L1 and R1 L3 and R3 are adjustable due to different card length Step 2 Fasten two screws on the hold on the bar marked in yellow after fitting the card by adjusting the pad...

Page 68: ...R 4 BIOS AND DRIVER 4 1 Entering BIOS Setup BIOS provides an interface for users to check and change system configuration The BIOS setup program is accessed by pressing the Del key when POST display o...

Page 69: ...s on Main menu System Date Set the date Use Tab to switch between date elements System Time Set the time Use Tab to switch between time elements Figure 4 2 BIOS Main Menu Figure 4 3 BIOS Advanced Menu...

Page 70: ...anderpool Technology Active Processor Cores Number of cores to enable in each processor package Hyper threading Enabled for Windows XP and Linux OS optimized for Hyper Threading Technology and disable...

Page 71: ...y ranges to be supported Intel R Speed shift Technology Enable Disable Intel Speed Shift Technology support Enabling will expose the CPPCv2 interface to allow for hardware controlled P states Turbo Mo...

Page 72: ...k to enable render standby support 4 3 2 2 GT Power Management Control Figure 4 3 2 2 GT Power Management Control ME State Set ME to Soft temporarily disabled AMT BIOS Features When disabled AMT BIOS...

Page 73: ...OS S4 sleep state This option may not be effective with some OS ACPI Sleep State Selects the highest ACPI sleep state the system will enter when the SUSPEND button is pressed S3 Video Repost Enables...

Page 74: ...86 SIO features an enhanced hardware monitor providing thermal fan speed and system voltages status monitoring Smart Fan Support Smart Fan Support Work with Full Speed if Smart Fan Support is Disabled...

Page 75: ...hange data Both computers should have the same or compatible settings Legacy Console Redirection Legacy Console Redirection Settings Serial Port for Out of Band Management Windows Emer ency Management...

Page 76: ...Decoding Globally Enables or Disables 64bit capable Devices to be Decoded in Above 4G Address Space Only if System Supports bot PCI Decoding Hot Plug Support Globally Enables or Disables Hot Plug supp...

Page 77: ...HTTP boot support Ipv6 PXE Support Enable Disable IPv6 PXE boot support Ipv6 HTTP Support Enable Disable IPv6 HTTP boot support IP6 Configuration Policy Set IP6 Configuration Policy PXE boot wait time...

Page 78: ...EDIATE execute the trap right away POSTPONED execute the trap during legacy boot HDD Connection Order Some OS require HDD handles to be adjusted i e OS is installed on drive 80h Boot option filter Thi...

Page 79: ...er USB Mass Storage Driver Support Enable disable USB mass storage driver support Port 60 64 Emulation Enables I O port 60h 64h emulation support This should be enabled for the complete USB keyboard l...

Page 80: ...anager Configuration Figure 4 4 BIOS Chipset Menu 4 4 1 System Agent SA Configuration VT d VT d capability Above 4GB MMIO BIOS assignment Enable disable above 4GB MemoryMappedIO BIOS assignment This i...

Page 81: ...ternal graphics Keep IGFX enabled based on the setup options GTT Size Select the GTT Size Aperture Size Select the Aperture Size Note Above 4GB MMIO BIOS assignment is automatically enabled when selec...

Page 82: ...IC Wake on LAN Enable or disable integrated LAN to wake the system The wake On LAN cannot be disabled if ME is on at Sx state Serial IRQ Mode Configure serial IRQ mode State After G3 Specify what stat...

Page 83: ...of PCH IO DMI Link ASPM Control Enable Disable the control of Active State Power Management on SA side of the DMI Link Native PCIE Enable PCIE Express Native Support Enable Disable PCI Express device...

Page 84: ...guration to enable or disable the storage features Aggressive LPM Support Enable PCH to aggressively enter link power state Options for each SATA port Port n Enable or disable SATA Port Hot Plug Desig...

Page 85: ...4 4 3 GPIOManager Configuration Figure 4 4 3 GPIOManager Configuration DVI VGA DDC channel selection DVI VGA channel selection for DVI I connecter System Fan 2 Speed System Fan 2 speed control High Mi...

Page 86: ...CX 1500 PEG User Manual BIOS AND DRIVER Administrator Password Set administrator password User Password Set user password Secure Boot Customizable Secure Boot Settings 4 5 Security Figure 4 5 BIOS Sec...

Page 87: ...emoved If the Set HDD User Password option is gray do power cycle to enable the option again 4 5 2 Security Boot Figure 4 5 2 Security Boot Settings Attempt Secure Boot Secure Boot activated when Plat...

Page 88: ...ite waiting Bootup NumLock State Select the keyboard NumLock state Quiet Boot Enables or disables Quiet Boot option Boot Option Sets the system boot order New Boot Option Policy Controls the placement...

Page 89: ...d Reset Reset system setup without saving any changes Save Changes Save Changes done so far to any of the setup options Discard Changes Discard Changes done so far to any of the setup options Default...

Page 90: ...hange in out direction in runtime process DIO definition is shown below Pin No Isolated DIO Non Isolated DIO Definition Pin No Isolated DIO Definition Non Isolated DIO Definition 1 DI 0 DIO 0 11 DO 0...

Page 91: ...O Connector DI_COM Pin 9 DI Pin 1 8 Source Mode PNP Power Supply 6 48V DC V V DIO Connector DI_COM Pin 9 DI Pin 1 8 DO reference circuit Sink Mode NPN Default Device 6 48V DC V V DIO Connector DIO_VDC...

Page 92: ...tion for sample Win10_32 bat and Win10_64 bat Installation for driver and installation to Framework 3 5 distribution for sample Uninstall_32 bat and Uninstall_64 bat Uninstallation for driver Run batc...

Page 93: ...decimal bitmask yes no Use for Read DIO Write button activate DI DIO input text read only DI DIO input state by hexadecimal bitmask on off Use for Read button activate DO DIO text read only DO DIO out...

Page 94: ...ction WDT setup text User setting WDT value unit second Use for Write button activate WDT counting text read only WDT counting by program timer after set WDT Shown after Write button action WDT setup...

Page 95: ...xists or initial error version is too old or machine not match BOOL GetDIO1Config BYTE Isolate_Type BYTE DI_NPN BYTE DO_ NPN WORD Mask BOOL GetDIO2Config BYTE Isolate_Type BYTE DI_NPN BYTE DO_ NPN WOR...

Page 96: ...Initial error or hardware problem BOOL GetDI1 BYTE DI BOOL GetDI2 BYTE DI GGet isolated DIO input DI DI 7 0 Input state pin setting by hexadecimal bitmask 1 High 0 Low Return TRUE 1 Success FALSE 0 F...

Page 97: ...n TRUE 1 Success FALSE 0 Fail Initial error or hardware problem BOOL GetWDT DWORD WDT Get watchdog timer setup WDT watchdog timer setup Unit second Range 0 65535 sec 1093 65535 min 65580 3932100 sec R...

Page 98: ...nfiguration SATA Mode Selection RAID Skylake platform Intel RST Premium Kaby Lake Coffee Lake platform C 1 2 UEFI Mode for RAID 1 Please select SATA device to RAID mode on BIOS menu Advanced SATA Conf...

Page 99: ...RCX 1500 PEG User Manual Appendix C 3 Use RST Legacy OROM Disabled Save Changes and Reset 4 Into BIOS menu again select Intel R Rapid Storage Technology on BIOS menu 5 Select Create RAID Volume on BI...

Page 100: ...are as follows 1 Install Chipset driver 2 Install Network driver 3 Install ME driver if available 4 Install Audio driver 5 Install VGA driver C 4 To Install Intel Rapid Storage Technology Software Yo...

Page 101: ...reate RAIDVolume on Rapid Storage Technology Software The system is featured with six SATA HDD s for RAID volume so there are three options to choose on this page Let s take RAID 1 as an example selec...

Page 102: ...C To start disk management tool select initialize disk Then add Logical Device for Windows access C 8 If One SATA HDD on RAID Volume is Out of use After RAID 1 volume is created you can see the figure...

Page 103: ...uildWhen Use DIFFERENT RAID HDD A warning will pop up to ask you if the disk is not a member of the original RAID volume If you press Rebuild it will replace the broken SATA HDD to the last SATA HDD o...

Page 104: ...USB Flash Transecnd 3 0 8GB USB 4 USB Flash Transecnd 3 0 8GB USB 5 USB Flash Kingston 3 0 16GB USB 6 USB Flash Kingston 3 0 32GB CFast Transcend CFX600 CFast 128GB SATA 0 Transcend SATA SSD420 128GB...

Page 105: ...i7 8700 12V 0 701A 08 41W CPU Power Input Power on and boot to Win10 64 bit Sleep Mode Idle status CPU usage less 3 Max Current Max Consumption Max Current Max Consumption Core i7 8700 12V 0 731A 08 7...

Page 106: ...ting Board RCX 1520 Memory Test Version 5 1 Burn In Test V8 1 E 2 Test Item Channel Memtest Bunin Flash BIOS Remove Battery 2 Socket 1 Socket 2 PASS PASS PASS PASS 2 Socket 3 Socket 4 PASS PASS PASS P...

Page 107: ...4S0 8GSSOCIK H03 25 C 25 C Innodisk 4G DDR4 2666 SO DIMM M4S0 4GSSN5IK H03 25 C 25 C Innodisk 4G DDR4 2666 SO DIMM M4S0 4GSSNCIK H03 25 C 25 C SLINK 8GB DDR4 2666 SO DIMM J48GSH1G8QHEC 25 C 25 C SLINK...

Page 108: ...PCIK H03 25 C 25 C Innodisk 8G DDR4 2666 SO DIMM M4D0 8GS1P5IK H03 25 C 25 C Innodisk 16G DDR4 2666 SO DIMM M4D0 AGS1Q5SJ H03 25 C 25 C Innodisk 16G DDR4 2666 SO DIMM M4D0 AGS1Q5IK H03 25 C 25 C Innod...

Page 109: ...B Innodisk 3MG2 P DGS25 64GD81BC1QC 64GB MEMXPRO M3A MI3MA1212802WN 128GB LITE ON K8 L1512 512GB K8 L1256 256GB Transcend TS128GSSD420K 128GB SSD370 TS64GSSD370I 64GB Kingston SUV400S37 120GB FORESEE...

Page 110: ...cow RCX 1500 PEG User Manual Appendix F FAPPENDIX F HowtoInstallPowerSupply F 1 1 RSP 1500 12 Adapter AC Cable RSP 1500 12 GREEN BLACK WHITE AC L AC N F 1 2 RSP 1500 12 Adapter DC Cable RSP 1500 12 V...

Page 111: ...4 Vecow RCX 1500 PEG User Manual Appendix F If more help is needed please contact Vecow technical support F 1 3 RSP 1500 12 Adapter PEG Cable F 1 4 RSP 1000 12 Adapter Cable RSP 1500 12 V V V V V V V...

Page 112: ...fications are subject to change without prior notice No part of this publication may be reproduced in any form or by any means electric photocopying or recording without prior authorization from the p...

Reviews: