17
©Vecow RCX-1500 PEG User Manual
GETTING TO KNOW YOUR RCX-1500 PEG
It is a 2-pin power-on/power-off switch through Phoenix Contact terminal block.
You could turn on or off the system power by using this contact. This terminal
block supports dual function on soft power-on/power-off (instant off or delay four
seconds), and suspend mode.
Pin No.
Definition
1
IGNITION
2
SW+
3
SW-
2.2.12 Remote Power On/Off Switch
Isolated
DIO 1
DVI-I
DP
Digital Display
|
LAN 1
10
COM 4
COM 3
COM 1
Isolated
DIO 2
DC-IN
V+ V-
SIM 2
SIM 1
RST
|
LAN 2
10
10
On | Off
IGN
V+
V-
PEG Power
There is a 16-bit (8-bit DI, 8-bit DO) connectors in the rear side. DI/DIO support NPN
(sink) and PNP (Source) mode, Each DI channel is equipped with a photocouper
for isolated protection. Each DO with isolator chip, Config by a Jumper for each DIO
connector.
2.2.13 Isolated DIO
Isolated
DIO 1
DVI-I
DP
Digital Display
|
LAN 1
10
COM 4
COM 3
COM 1
Isolated
DIO 2
DC-IN
V+ V-
SIM 2
SIM 1
RST
|
LAN 2
10
10
On | Off
IGN
V+
V-
PEG Power
DO Safety-Related Certifications :
• 4242-VPK Basic Isolation per DIN V VDE V 0884-10
and DIN EN 61010-1
• 3-KVRMS Isolation for 1 minute per UL 1577
• CSA Component Acceptance Notice 5A, IEC 60950-1
and IEC 61010-1 End Equipment Standards
• GB4943.1-2011 CQC Certified
D I
PIN 1 ~ 8
DO
PIN 11 ~ 18
1
10
12
20
Isolated
DI