35
©Vecow ECX-3000 PEG User Manual
GETTING TO KNOW YOUR ECX-3000 PEG
2.3.2 Remote Power On/Off Switch Terminal Block
2.3.3 Isolated DIO
2.3.3.1 ECX-3800/3600/3400/3200/3200MX PEG Series
COM 1
COM 3
COM 2
COM 4
V+ V
DC-IN
IGN
On / Off
COM 1
COM 3
COM 2
COM 4
V+ V
DC-IN
IGN
On / Off
It is a 3-pin power-on or power-off switch through Phoenix Contact terminal
block. You could turn on or off the system power by using this contact. This
terminal block supports dual function of soft power-on/ power-off (instant off or
delay 4 second), and suspend mode.
Pin No.
Definition
Pin No.
Definition
1
Ignition
2
SW+
3
SW-
There is a 16-bit (8-bit DI, 8-bit DO) connectors in the rear side. DI/DIO support
NPN (sink) and PNP (Source) mode, Each DI channel is equipped with a
photocouper for isolated protection. Each DO with isolator chip, Config by a
Jumper for each DIO connector. DO Safety-Related Certifications :
• 4242-VPK Basic Isolation per DIN V VDE V 0884-10
and DIN EN 61010-1
• 3-KVRMS Isolation for 1 minute per UL 1577
• CSA Component Acceptance Notice 5A, IEC 60950-1
and IEC 61010-1 End Equipment Standards
• GB4943.1-2011 CQC Certified
Isolate
d
Isolated
DI
O
DIO
D I
PIN 1 ~ 8
DO
PIN 11 ~ 18
20
11
10
1
Summary of Contents for ECX-3000 PEG
Page 81: ...73 Vecow ECX 3000 PEG User Manual SYSTEM SETUP Step 2 Take out heat sink...
Page 88: ...80 Vecow ECX 3000 PEG User Manual SYSTEM SETUP Step 2 Open bottom cover...
Page 93: ...85 Vecow ECX 3000 PEG User Manual SYSTEM SETUP Step 2 Open bottom cover add in card cover...
Page 99: ...91 Vecow ECX 3000 PEG User Manual SYSTEM SETUP Step 2 Open bottom cover...