VE Valley Electronics LADY-COMP Instructions For Use Manual Download Page 19

AAA

AAA

Insert SD card

11. IMPORTANT INFORMATION

Battery compartment 
and serial number

Mini USB port

Serial interface 

(for servicing only)

Recessed SD card 

compartment

Notches for closing 

the device

Measuring sensor port

The measuring sensor can 
be replaced at any time by 
unplugging it from the port.

Analysing cycle data – reading out data:

Register at www.lady-comp.de. You will receive your personal access 
code. You can read out your data via a mini USB cable from there.
Our experienced support team will help you with analysing your data 
and be happy to advise you on your personal cycle curve.

[email protected] or call us for any further queries

Mini USB cable

Your LADY-COMP

®

 comes with a mini USB 

cable included in the product box. This cable 
allows you to transfer your data to a PC. 
You can also have your cycle data analysed by 
your local retailer or by VE Valley Electronics 
GmbH. To do this, go to our website or e-mail-

Risk of data loss excluded

Any risk of loss of data stored on your compu-
ter due to empty accu chargers / batteries can 
be excluded.

Software programme

The software uses previously input base data, 
right from the start. The more regularly you 
measure your temperature, the faster the 
device will become familiar with your indivi-
dual cycle and be able to interpret it. It will 
show more and more green (infertile) 
days and the red (fertile) days will be increa-
singly narrowed down.

Nightshifts

Set and activate the alarm by entering the 
required measurement time. Let yourself be 
woken by the tone the next morning and 
measure your temperature as usual. Do like-
wise the next time you change shifts.

Upgrades: Micro SD card

Should you wish to update the software at 
a later stage or to upgrade it for further 
functionality, we will send you an SD card.
- Open device as described on page 6.
- Remove batteries.
- Insert SD card.
- After completing your update/upgrade, we 
recommend removing the SD card in order 
to avoid unnecessary power consumption and 
ensure a quick reboot of the device.

After the pill 
(or other hormone preparations)

Before you begin, you must discontinue taking 
the pill. The first bleeding after discontinuing 
the pill is a pill-induced withdrawal bleeding, 
not a period. Do not input «M» in this case.

Prognosis

The indicators used to predict ovulation and/
or for family planning (boy/girl) are forecasts 
and based on the data gathered from previous 
cycles. Once a cycle is complete and the 
next period commences, the device recalcula-
tes the previous cycle, as it is now possible 
to define the exact time of ovulation. This is 
done on day 4 of the new cycle.

Restart after interruption

The date, year, and time will continue to run 
automatically. The measurement period will be 
unblocked for a new input as soon as you 
stop measuring, and has to be re-set by setting 
the alarm. To do this, set the alarm for the 
following morning (before 12pm) and continue 
the use as usual.

AAA power accu charger

You may order the required charger from us. 
Insert 2 AAA accus in the charger. The pro-
gress will then be displayed on the charger.

Pearl Index

The Pearl Index is a medical value that indi-
cates the safety of a particular contraception 
method. Our daily fertility indicator has 
a Pearl Index of 0.7 or, to put it simply, is a 
99.3pc safe.

Travel and time zones

When travelling to other time zones you may 
reset the date and time to the current local 
time. Your computer will be ready for measu-
ring the next day, at the desired time of day.

Example:

If one woman out of 100 who uses contra-
ception for a year becomes pregnant, this 
corresponds to a Pearl Index of 1.0.

Summer and winter time

Set the clock to summer or winter time, 
as described on page 9.

LADY-COMP – 36

37 – LADY-COMP

Summary of Contents for LADY-COMP

Page 1: ...INSTRUCTIONS FOR USE THE INTELLIGENT CYCLE COMPUTERS...

Page 2: ...or LADY COMP baby whether controlling pregnancy the natural way or planning for a family in any case you have made a good decision And ten thousands of women have done so before you They have all been...

Page 3: ...Y COMP baby only 23 Cycle curve 24 Personal inputs 26 10 Settings Body Mass Index BMI 27 Default settings 29 Temperature time unit 30 Personal comments 30 Gender prognosis on off 31 Erasing data 32 Te...

Page 4: ...ically erased as soon as you do your first measurement or input your own menstruation data The default values will reappear as soon as your own data is erased 3 Insert the batteries Insert the power a...

Page 5: ...9 6 10 48 12 3 9 6 10 50 Time date Alarm Menstruation Measurement Return Settings Cycle calendar Pregnancy planning Cycle planning statistics The available menu levels may vary depending on which LADY...

Page 6: ...he date back no measure ment can be recorded the next day You can also set the date ahead by only one day It is thus impossib le to enter a false date This enables you to correct the date when travell...

Page 7: ...any measurement or M input for some time 4 days and a new cycle was expected to begin during this time period this warning will remind you to catch up with your inputs To do activate M post hoc In th...

Page 8: ...time does not coincide with the time you wake up the next day Tips for the measurement period The measurement period is displayed in form of a measurement symbol on the home screen Within the measure...

Page 9: ...curve and your fertility status based on existing values Temperature increases due to the flu a lack of sleep excessive alcohol consumption and or the use of medicinal drugs with a thermal effect are...

Page 10: ...9 7 8 3 5 1 4 1 Return is on Flip through months Press Return The cycle calendar shows you the fertility curve of your cycles as measured in the last months You may also call up a menstrua tion progn...

Page 11: ...tion date itself This prognosis is based on calculation 02 02 05 05 11 36 30 08 08 11 36 30 09 08 11 36 30 10 08 Conception date and birth date Pregnancy indicator Return is on Click Press Return Retu...

Page 12: ...nomenon is characterized by a shorter high temperature phase and or a lower temperature increase This information is important when planning for a child and for an exact analysis of your cycle curve T...

Page 13: ...lity First day displayed Last day displayed Lunar phase Ovulation day Menstruation Intercourse 37 5 36 5 37 0 36 0 06 07 04 05 37 5 36 5 37 0 36 0 06 07 04 05 37 5 36 5 37 0 36 0 09 10 07 07 37 5 36 5...

Page 14: ...s Inputs may be given up to three days later 10 SETTINGS MEDIKAMENT 08 08 PARTY SCHICHT MEDIKAMENT MEDIKAMENT 08 08 MEDIKAMENT 08 08 Click Select input field Click Select date Yes Return is on Click P...

Page 15: ...fault setting 1980 Select year Click Input year Confirm year Default setting 170 Select height Click Enter height Confirm height Default setting 60 To calculate the BMI Select weight Click Enter weigh...

Page 16: ...oneous allocation of your inputs C Celsius F Fahrenheit Return is on Click Celsius Fahrenheit Return Select Temperature time unit Personal comments Gender prognosis on off Return is on Click Indicator...

Page 17: ...ctioning To cancel the measurement process keep the OK button pressed for 3 seconds Erase data Test measurement Product information 10 08 10 08 36 48 10 08 36 48 Starts automatically Measurement symbo...

Page 18: ...button click tone Luminosity Volume Button click tone Alarm tone SETTINGS SETTINGS Return is on Displace luminosity control Press Return Return is on Displace volume control Press Return LADY COMP an...

Page 19: ...we will send you an SD card Open device as described on page 6 Remove batteries Insert SD card After completing your update upgrade we recommend removing the SD card in order to avoid unnecessary powe...

Page 20: ...a software update is interrupted and the software cannot be completely restored e g because the power accus are empty The code following the dash indicates the exact error cause Error message For erro...

Page 21: ...ater avoid aggressive cleaning products Housing Wipe with a slightly moist cloth and glass cleaner Please keep water or any other liquids get ting on in the device or sensor as this can lead to a defe...

Page 22: ...the ideal moment for a planned pregnancy gender prognosis and the conception date as well as to calculate the birth date Service and support To replace a defective measuring sensor you may order it f...

Page 23: ...t of a typical business or hospital environment If the user of the LADY COMP or LADY COMP baby device wishes to continue using the device during a power cut we recommend connecting the LADY COMP or LA...

Page 24: ...rding to on site tests Interference is possible in the vicinity of equipment that carries the following symbol Annotation 1 UT is the alternating supply voltage prior to application of test levels Ann...

Page 25: ...Home screen 7 Information about the device 33 Inputting M after measurement 15 Inputting M post hoc 12 Inserting the batteries 6 Intended use 42 LADY COMP 8 22 LADY COMP baby 8 19 20 21 22 23 LADY CO...

Page 26: ...device 7 Taking a measurement 13 14 Technics 40 Temperature increase 23 Test measurement 33 Temperature time unit 30 Travelling time zones 37 USB 41 USB mini cable 36 USB not functioning correctly 38...

Page 27: ...GmbH Breite 2 D 82418 Murnau Phone 49 0 8841 48928 0 Fax 49 0 8841 48928 24 info lady comp de www lady comp de Sales Switzerland Valley Electronics AG Marienstrasse 16 CH 8003 Z rich Phone 41 44 577 6...

Reviews: