![vds E107 Instruction Manual Download Page 6](http://html.mh-extra.com/html/vds/e107/e107_instruction-manual_858274006.webp)
Instruction Manual
OPTIONS SELECTOR
OPERATING INSTRUCTIONS
OPTION 1 - Automatic closing
ON
Door closes automatically after waiting the a.c.time
OFF
Door does not close automatically
OPTION 2 - Disable stop on opening
OPTION 3 - Radio open/Alternative
Radio card works as alternative button
OPTION 4 - DeadMan
ON
Opening the alternative button is disabled
OFF
If alternative button is pressed door stops
ON
OFF
Radio card works as a opener
ON
DeadMan functionality enabled
OFF
DeadMan functionality disabled
OPTION 5 - Double time
ON
Working time range from 1m10sec to 2m10sec
OFF
working time range from 6-8secs to 1m25sec
OPTION 6 - Garage light
ON
Garage lights goes on when the door is opening
OFF
2 secs impulse
OPTION 7 - Safety edge photocell
ON
Door inverts during 1 sec. During opening and closing.
OFF
During opening, safety opening activates
OPTION 8 - Pre-flashing
ON
Flashing output ENABLED before starting, open and close
OFF
Flashing output DISABLED before starting, open and close
The control panel can be activated by Test CI P.ALTER), via the radio card, or by the open, close and stop buttons.
Manoeuvres can be finalised via the following: limit switch activation or end of working time
If the ALT button is pushed while the door is opening it stops and does not close the door.
Pressing the STOP button stops the door. It is necessary to push OPEN or CLOSE buttons to reactivate the operation.
If the safety input is activated whilst the door is closing then the door will open.
The garage light contact is activated when the door is opening & deactivated after 2 seconds.
If I4 is ON y I3 ON the control panel gives the order for automatic opening and closing of the dead mans switch.
If I4 is ON y I3 OFF the control panel gives the order to open and close the dead mans switch.
•
OPTIONAL
NOT AVAILABLE
STANDARD
RADIO
CARD
WIREL
ES
SBAN
D
RADIO
CARD
LO
OP
DETECT
O
R
LO
OP
DETECT
O
R
PHO
TO
CEL
L IN
HIBIT
O
R
EL
ECTRO
L
OCK
G
ARAG
E
LIGHT
PRE F
LA
SHING
TRAF
FIC L
IGHT
THREEPHA
SE
SWIT
CH
EMERG
EN
CY ST
O
P
SAF
ET
Y EDG
E INPUT
6AM
P. F
USES
VARIST
O
R
ZEN
ER DIODES
PHO
TO
CEL
L INPUT
DEAD
M
AN
PHO
TO
CEL
L TEST
SAF
ET
Y EDG
E TEST
O
PEN CL
O
SE
LIM
IT SWIT
CH
AL
TERN
ATIVE
BUT
TO
N
PRES
SURE
W
AVE
SWIT
CH
AUT
O
M
ATIC DOWN
TIM
E (
TEM
PO
RIZER)
O
PEN
IN
G
TIME
(TEM
PO
RIZER)
CL
OSING
TIM
E
(TEMPO
RIZER)
DRIVE
PO
WER (
TEMPO
RIZER)
DEPHA
SE(
DRIVE
1 &
2 (
TEM
PO
RIZER)
CL
OSE SWIT
CH
O
PEN SWIT
CH
ST
O
P
BUT
TO
N
BUF
FER
CL
OSING
CL
OSE BY S
AF
ET
Y
CONT
ACT
AUT
O
M
ATIC CL
OSING
INHIBITIO
N
ST
OP
O
N
O
PENING
DO
UBL
E
TIM
E
DIGIT
AL
TIM
E
HO
URL
Y
IMPUL
SE
PAR
TIAL
/
TO
TAL
IN
VERSION
TIM
ES
AUT
O
M
ATIC CL
O
SIN
G
F
O
R L
IM
IT SWIT
CH
AUT
O
M
ATIC F
RECUEN
CY AGIL
IT
Y (B
ridge S
.)
12
V
O
UTPUT
FREE
TENSIO
N
INPUT
CO
N
TACT 0V
RADIO
PRO
G
RAM
M
ING
BRIDG
E
SEL
ECT
O
R
FRECUENCY
CHANN
EL
SEL
ECT
O
R
230V
380v
433M
Hz
868M
Hz
1 DRIVE
2 DRIVE
WIREL
ES
SBAN
D RECEIVER
ACCESSORIES
SAFETY
SETTINGS
•
••
••••
( EURO380 M1 )
WARNING!!
AN ACCESSIBLE SWITCH, TO TURN OFF THE EQUIPMENT,MUST BE INSTALLED FOR SYSTEMS
THAT ARE ALWAYS CONNECTED.
BEFORE INSTALLING MAKE SURE THE SUPPLY VOLTAGE IS SWITCHED OFF.
GB