41
Key for circuit diagram
S1 On/Off switch for navigation instruments
S2 On/Off switch for instrument lighting
F1 Fuse for navigation instruments (5 A)
F2 Fuse for instrument lighting (5 A)
Recommended cable section: 1.5 mm
2
Cable lengths
Wind sensor - indicating instrument
20 m max.
Indicating instrument - second instrument 10 m max.
Second instrument - third instrument
10 m max.
Technical data
Measuring principle:
Vane with inductive transmission, Cup anemo-
meter with Hall chip
Accuracy
direction ± 3°
speed ± 2 km/h (0 60 km/h)
Resolution:
Direction 1°, Speed 1 km/h
Supply voltage
10.8 to 30 V DC
Current consumption: about 140 mA at 12 V DC without lighting
about 300 mA with lighting
Operating temperature 10 to +60°C
Type of protection
IP 65 at front per IEC 529
EMC protection
CE: EN 50081-1, EN 50082-1
Dimensions:
Indicating instrument:
Front ring diam..: 105 mm
Installation diam..: 86 mm
Installation depth (with union nut): 56 mm
Installation depth (with bracket): 90 mm
Compass sensor: See figure page 37
Technical modifications reserved.
INSTALLATION / DATA
olwind_e.qxd 21.06.99 13:35 Seite 41