Configure and calibrate the fuel level sensor
1. Press
to access the main menu and then
scroll and select
SENSOR CONFIG
.
2. Scroll and select
Fuel
.
3. Select
Tank volume
, to set tank capacity.
4. Scroll and select
Sensor type
, then scroll and
select the sensor type.
5. Scroll and select
Calibration
, then select the
one or five point calibration procedure (
Do 1
point cal
/
Do 5 point cal
): calibration
instructions and the ohm value read in real-time
by the sensor
[A]
appear.
6. Empty the tank and wait for the read value to
stabilize. Then confirm by pressing the knob.
7. For five point calibration, proceed with all
calibration points by following the on-screen
instructions.
8. Hold down
to return to the data pages.
Delete the calibration on the fuel level sensor
1. Press
to access the main menu and then scroll and select
SENSOR CONFIG
.
2. Scroll and select
Fuel
.
3. Scroll and select
Calibration
, then select
Delete cal
: default factory settings are restored.
4. Hold down
to return to the data pages.
Configure the other sensors
Following is the procedure to configure the compass and wind, pressure, depth, rudder angle and speed
sensors.
1. Press
to access the main menu and then scroll and select
SENSOR CONFIG
.
2. Scroll and select the type of sensor (e.g.
Rudder
).
3. Scroll and select the configuration parameter (e.g.
Rudder offset
) and set the value. To view factory
settings, see
"Sensor types" on the facing page
NOTICE
: confirm all the digits to save the value.
4. Hold down
to return to the data pages.
Sensor configuration