Care and Service
96
VideoJet 100
When the transmission is completed, the message
transfer
complete
will be displayed and the green LED flashes. The new
software will now be unpacked and the flash EPROM will be repro-
grammed.
When the green LED stops flashing, programming is complete. An
automatic reset of the device is carried out and the FTP connection
is deactivated.
"
Press the keys [Ctrl] + [Break] simultaneously to terminate the FTP
session.
Checking the network
The connection between two IP addresses can be checked using
the command
ping
. You can thus check whether the VideoJet 100
in the network is active.
"
Open the DOS input window
"
Enter the command
ping
followed by the IP address of the
VideoJet 100.
When the VideoJet 100 is found, you receive in response:
Reply
from ...
, followed by the number of bytes transmitted and the
transmission time in ms. Otherwise the VideoJet 100 cannot be
addressed via the network. This can have the following causes:
!
The VideoJet 100 is not correctly connected to the network. In
this case, check the connecting leads.
!
The VideoJet 100 is not correctly integrated into the network.
Check the IP address, the subnet mask and the gateway IP.
Attention!
On no account interrupt the installation of the software. An interrup-
tion will result in damage to the flash EPROM. This can result in the
device being no longer addressable and having to be replaced.
Summary of Contents for VideoJet 100
Page 1: ...VideoJet 100 VideoJet 100 VideoJet 100 VideoJet 100 Manual...
Page 5: ...Contents 5 VideoJet 100 Application examples 105 Specifications 107 Chapter 9 Index 109...
Page 6: ...Contents 6 VideoJet 100...
Page 10: ...Preface 10 VideoJet 100...
Page 28: ...Installation 28 VideoJet 100...
Page 94: ...Operation 94 VideoJet 100...
Page 98: ...Care and Service 98 VideoJet 100...
Page 116: ...Index 116 VideoJet 100...
Page 117: ...117 VideoJet 100...