Vacuum Packaging Machines 07P ...
Malfunctions
11.2
Possible operating malfunctions
Malfunctions Cause
Remedy
Machine does not appear on
the display after turning on the
main switch
El. Supply not ensured
Mains automatic circuit breaker (Fig.
3/2, Pos. 18) triggered
Fine wire fuse (Fig. 3/2, Pos. 17)
burnt through
Check El. connections
Switch on mains automatic circuit
breaker
Replace fine wire fuse 16 AT
Main switch does not remain in
the On position
Main switch defective
Fine wire fuse (Fig. 3/2, Pos.6) burnt
through
Interruption in 48 VAC supply
Excess temperature switch at the
sealing transformer has been
triggered
Voltage setting at the transformer
incorrect
Check main switch and possibly replace
Replace fine wire fuse 2 AT
Call the VC999 Customer Service Dept.
Allow sealing transformer to cool off
Call the VC999 Customer Service Dept.
Keyboard and display do not
react
Malfunction of the microprocessor by
power supply
Defective microprocessor
Turn off main switch and after ca. 10
seconds switch on again. Possibly
repeat again.
Call the VC999 Customer Service Dept.
Platform does not move
products out
Transport time in the packaging
program set to “0 “
Transport type in service program on
“OFF
“
Set transport time in accordance with
Chapter 10.6.10 "Transport time"
Set mode of transport in the service
program to “ON”.
Program cannot be altered
anymore
Programs locked
Set number of locked programs to “0”,
see Chapter 10.6.12 "Number of locked
programs"
Program cannot be selected
Key switch closed
Open key switch, see Chapter 10.7.4
"Key switch"
Malfunctioning seal
Sealing time not properly set
Teflon tape on sealing bar damaged
Power contact springs on sealing bar
make no contact
Pressure too low
Set sealing time
Replace Teflon Chapter, see Chapter
13.2.2 "Maintenance sealing bar"
Clean power contact springs
Call the VC999 Customer Service Dept.
Vacuuming too weak
The partner machine is vacuuming
with evaporation
Condensate in measuring system
Switch off VVO extension
Call the VC999 Customer Service Dept.
Ruined products
Bag material unsuitable
Cooling chain was interrupted
See Chapter 2.1.2.1 "Vacuum bag"
Dispose packaging properly
Partner machine not ready
(Interconnection
s. Chap. 3.3.2)
Main switch not turned on
Machine not in initial position or in
sleep mode
Error in the wiring of the
interconnection
Turn on main switch
Call the VC999 Customer Service Dept.
Page 44/74
Art. no. 527.763
2003-11-05
Summary of Contents for 07P Series
Page 2: ......
Page 4: ......
Page 69: ...Vacuum Packaging Machines 07P Circuit diagrams 2003 11 05 Art no 527 763 Page 69 74...
Page 70: ...Vacuum Packaging Machines 07P Circuit diagrams Page 70 74 Art no 527 763 2003 11 05...
Page 71: ...Vacuum Packaging Machines 07P Circuit diagrams 2003 11 05 Art no 527 763 Page 71 74...