ADJUSTMENTS.
WARNING: These operations must be carried out by a qualified
technician operating with extreme care.
12.1,
ADJUSTING THE BOILER TEMPERATURE/
PRESSURE.
You can adjust the pressure and hence the temperature of the water in the boiler by
means of the pressure switch viewing it on the pressure gauge (1).
•
Remove the cup heating plate (2) as described in the paragraph on installation.
•
Act on the screw (3) of the pressure switch turning it CLOCKWISE to decrease
the pressure and ANTICLOCKWISE to increase it.