Series 292
DISMOUNTING AND STORAGE
603585EA
Edition 2015-05-18
27/31
8.1
Dismounting
NOTICE
Valve in open position
Valve body and plate may get damaged if valve is in open position.
Close the valve before dismounting the valve from the system.
1. Disconnect compressed air supply.
2. Disconnect electrical power supply.
3. Dismount valve from system.
8.2
Storage
NOTICE
Wrong storage
Inappropriate temperatures and humidity may cause damage to the product.
Valve must be stored at:
– relative humidity between 10% and 70%
– temperature b10 °C and +50 °C
– non-condensing environment
NOTICE
Inappropriate packaging
Product may get damaged if inappropriate packaging material is used.
Always use the original packaging material and handle product with care.
1. Clean / decontaminate valve.
2. Cover all valve openings with a protective foil.
3. Pack valve appropriately, by using the original packaging material.